AC-PM-Analog-MIB DEFINITIONS ::= BEGIN


    IMPORTS
       

        OBJECT-TYPE, 
        MODULE-IDENTITY                             FROM SNMPv2-SMI
        TAddress, 
        DisplayString, 
        DateAndTime, TEXTUAL-CONVENTION             FROM SNMPv2-TC
        IpAddress                                   FROM RFC1155-SMI
        Unsigned32,
		Integer32,
        enterprises                                 FROM SNMPv2-SMI
		SnmpAdminString								FROM SNMP-FRAMEWORK-MIB
		audioCodes,       
		acRegistrations,
		acGeneric, 
		acProducts,acBoardMibs,acPerformance		FROM AUDIOCODES-TYPES-MIB;

       
acPMAnalog  MODULE-IDENTITY       
    LAST-UPDATED "201208020214Z"          --Thursday, August 2 2012
    ORGANIZATION "AudioCodes Ltd"
    CONTACT-INFO
    "Postal: Support
			 AudioCodes LTD
             1 Hayarden Street
             Airport City 
			 Lod, ISRAEL 70151
     Tel:    972-3-9764000
     Fax:    972-3-9764040
     Email:  support@audiocodes.com
     Web:    www.audiocodes.com"		
		

    DESCRIPTION       
    "The AC-PM-Analog MIB offers performance monitoring
For the Analog related elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-Analog MIB, and the 
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.

Note  - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."



    ::= {acPerformance 9}  








     acPMAnalogConfiguration OBJECT IDENTIFIER ::= {acPMAnalog 1}


     acPMAnalogConfigurationPeriodLength OBJECT-TYPE
       SYNTAX Unsigned32 (0..894780)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Length of monitoring intervals for entire MIB.
Time is in minutes."
       ::= {acPMAnalogConfiguration 1}



     acPMAnalogConfigurationResetTotalCounters OBJECT-TYPE
       SYNTAX INTEGER {
                  resetCountersDone(1)
,
                  resetTotalCounters(2)

                  }
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Total-Counters Reset.  To reset the total counters, set the
value of this object to resetTotalCounters(2)."
       ::= {acPMAnalogConfiguration 2}



     acPMAnalogUtilsAttributes OBJECT IDENTIFIER ::= {acPMAnalogConfiguration 31}


     acPMAnalogUtilsAttributesOffHookChannelsHighThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "High threshold."
       ::= {acPMAnalogUtilsAttributes 1}



     acPMAnalogUtilsAttributesOffHookChannelsLowThreshold OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-write
       STATUS current
       DESCRIPTION
           "Low threshold."
       ::= {acPMAnalogUtilsAttributes 2}



     acPMAnalogData OBJECT IDENTIFIER ::= {acPMAnalog 2}


     acPMAnalogDataAcPMAnalogTimeFromStartOfInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The time in seconds since the start of the current interval.
MIB specific."
       ::= {acPMAnalogData 1}



     acPMAnalogUtils OBJECT IDENTIFIER ::= {acPMAnalogData 31}


     -- ****************************************
     -- acPMOffHookChannels table decleration
     -- ****************************************
     acPMOffHookChannelsTable OBJECT-TYPE
       SYNTAX SEQUENCE OF AcPMOffHookChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Number of active (off-hook) analog lines."
       ::= {acPMAnalogUtils 21}



     -- ****************************************
     -- acPMOffHookChannels table entry
     -- ****************************************
     acPMOffHookChannelsEntry OBJECT-TYPE
       SYNTAX AcPMOffHookChannelsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           ""
       INDEX {acPMOffHookChannelsInterval}
       ::= {acPMOffHookChannelsTable 1}



     -- ****************************************
     -- acPMOffHookChannels TABLE
     -- ****************************************
     AcPMOffHookChannelsEntry ::= SEQUENCE {
       acPMOffHookChannelsInterval                     Unsigned32,
       acPMOffHookChannelsVal                          Gauge32,
       acPMOffHookChannelsAverage                      Integer32,
       acPMOffHookChannelsMax                          Integer32,
       acPMOffHookChannelsMin                          Integer32,
       acPMOffHookChannelsVolume                       Integer32,
       acPMOffHookChannelsTimeBelowLowThreshold        Integer32,
       acPMOffHookChannelsTimeBetweenThresholds        Integer32,
       acPMOffHookChannelsTimeAboveHighThreshold       Integer32,
       acPMOffHookChannelsFullDayAverage               Integer32
     }



     acPMOffHookChannelsInterval OBJECT-TYPE
       SYNTAX Unsigned32 (0..2)
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
       ::= {acPMOffHookChannelsEntry 1}



     acPMOffHookChannelsVal OBJECT-TYPE
       SYNTAX Gauge32
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Value of gauge or counter."
       ::= {acPMOffHookChannelsEntry 2}



     acPMOffHookChannelsAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Average value with in the period time."
       ::= {acPMOffHookChannelsEntry 3}



     acPMOffHookChannelsMax OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Maximum value with in the period time."
       ::= {acPMOffHookChannelsEntry 4}



     acPMOffHookChannelsMin OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Minimum value with in the period time."
       ::= {acPMOffHookChannelsEntry 5}



     acPMOffHookChannelsVolume OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Activity volume."
       ::= {acPMOffHookChannelsEntry 6}



     acPMOffHookChannelsTimeBelowLowThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is below what was determined
as the low threshold."
       ::= {acPMOffHookChannelsEntry 7}



     acPMOffHookChannelsTimeBetweenThresholds OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is above what was determined
as the high threshold."
       ::= {acPMOffHookChannelsEntry 8}



     acPMOffHookChannelsTimeAboveHighThreshold OBJECT-TYPE
       SYNTAX Integer32 (-1..100)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
       ::= {acPMOffHookChannelsEntry 9}



     acPMOffHookChannelsFullDayAverage OBJECT-TYPE
       SYNTAX Integer32 (-1..2147483647)
       MAX-ACCESS read-only
       STATUS current
       DESCRIPTION
           "The average of full 24 hours."
       ::= {acPMOffHookChannelsEntry 10}





END