-- This file was included in Ciena MIB release MIBS-CIENA-CES-08-07-00-024
--
-- CIENA-CES-OAM-MIB.my

 CIENA-CES-OAM-MIB DEFINITIONS ::= BEGIN
 
  IMPORTS
   Integer32, Unsigned32, Counter32, Counter64, NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY                 
         FROM SNMPv2-SMI   
   TimeStamp
         FROM SNMPv2-TC
   cienaGlobalSeverity, cienaGlobalMacAddress
   		FROM CIENA-GLOBAL-MIB    
   CienaStatsClear
   		FROM CIENA-TC
   cienaCesNotifications, cienaCesStatistics
        FROM CIENA-SMI;
        
         
    cienaCesOamMibModule MODULE-IDENTITY 
              LAST-UPDATED "201812050000Z"
              ORGANIZATION "Ciena Corp."
              CONTACT-INFO
              "   Mib Meister
                  7035 Ridge Road
                  Hanover, Maryland 21076
                  USA
                  Phone:  +1 800 921 1144
                  Email:  support@ciena.com"
	      DESCRIPTION
		       "This module defines the EFM OAM statistics objects and also the objects required for
		       EFM OAM related notifications."

              REVISION "201812050000Z"
              DESCRIPTION
                       "Removed Integer32 range from cienaCesOamEventLogPort to
                        accommodate PGID range available on some devices."

              REVISION "201706070000Z"
              DESCRIPTION
                       "Updated contact info."

              REVISION "201701090000Z"
              DESCRIPTION
                       "Added cienaCesOamEventNotifChannelNumber to CienaCesOamEventLogEntry and
                        cienaCesOamLinkEventTrap"

              REVISION "201602192049Z"
	      DESCRIPTION
		       "Adding new Tables to the Oam Mib : 
		        cienaCesOamTable,
		        cienaCesOamPeerTable,
			cienaCesOamLoopbackTable,
                        cienaCesOamSystemEnableDisable,
			cienaCesOamEventConfigTable."

	      REVISION "201005100000Z"
	      DESCRIPTION
		       "Initial creation."
          ::= { cienaCesStatistics 5 }
        
--
-- Node definitions
--
        
 cienaCesOamMIB OBJECT IDENTIFIER ::= { cienaCesOamMibModule 1 }
 cienaCesOamStatistics OBJECT IDENTIFIER ::= { cienaCesOamMIB 1 } 

 cienaCesOamConformance OBJECT IDENTIFIER ::= { cienaCesOamMIB 2 }
 cienaCesOamGroups OBJECT IDENTIFIER ::= { cienaCesOamConformance 2 }
 cienaCesOamCompliances OBJECT IDENTIFIER ::= { cienaCesOamConformance 1 }

 cienaCesOamNotifMIBNotificationPrefix  OBJECT IDENTIFIER ::= { cienaCesNotifications 15 } 
 cienaCesOamNotifMIBNotification        OBJECT IDENTIFIER ::= { cienaCesOamNotifMIBNotificationPrefix 0 }

 cienaCesOamStatsTable OBJECT-TYPE
      SYNTAX SEQUENCE OF CienaCesOamStatsEntry
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
         "Statistics for the OAM function on a particular Ethernet-like
          interface."
      ::= { cienaCesOamStatistics 1 }

  cienaCesOamStatsEntry OBJECT-TYPE
       SYNTAX CienaCesOamStatsEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
           "An entry in the table, containing statistical information on
            the Ethernet OAM function for a single Ethernet-like interface."
       INDEX { cienaCesOamStatsPort }
       ::= { cienaCesOamStatsTable 1 }

  CienaCesOamStatsEntry ::=  SEQUENCE { 
       cienaCesOamInformationTx				           Counter32,
       cienaCesOamInformationRx             	       Counter32,
       cienaCesOamUniqueEventNotificationTx            Counter32,
       cienaCesOamUniqueEventNotificationRx            Counter32,
       cienaCesOamLoopbackControlTx                    Counter32,
       cienaCesOamLoopbackControlRx                    Counter32,
       cienaCesOamVariableRequestTx                    Counter32,
       cienaCesOamVariableRequestRx                    Counter32,
       cienaCesOamVariableResponseTx                   Counter32,
       cienaCesOamVariableResponseRx                   Counter32,
       cienaCesOamOrgSpecificTx                        Counter32,
       cienaCesOamOrgSpecificRx                        Counter32,
       cienaCesOamUnsupportedCodesTx                   Counter32,
       cienaCesOamUnsupportedCodesRx                   Counter32,
       cienaCesOamframesLostDueToOam                   Counter32,
       cienaCesOamStatsPort                            Integer32,
       cienaCesOamDuplicateEventNotificationTx         Counter32,
       cienaCesOamDuplicateEventNotificationRx         Counter32
  }

 cienaCesOamInformationTx OBJECT-TYPE
     SYNTAX Counter32
     UNITS "frames"
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "A count of the number of Information OAMPDUs transmitted on
          this interface.
                                  
          An Information OAMPDU is indicated by a valid frame with (1)
          destination MAC address equal to that of the reserved MAC
          address for Slow Protocols (See 43B of [802.3ah]), (2) a
          lengthOrType field equal to the reserved type for Slow
          Protocols, (3) a Slow Protocols subtype equal to that of the
          subtype reserved for OAM, and (4) an OAMPDU code equal to the
          OAM Information code.  
                                  
          Discontinuities of this counter can occur at re-initialization
          of the management system, and at other times as indicated by
          the value of the ifCounterDiscontinuityTime."
     ::= { cienaCesOamStatsEntry 1 }

 cienaCesOamInformationRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
          "A count of the number of Information OAMPDUs received on this interface.
                                  
           An Information OAMPDU is indicated by a valid frame with (1)
           destination MAC address equal to that of the reserved MAC
           address for Slow Protocols (See 43B of [802.3ah]), (2) a
           lengthOrType field equal to the reserved type for Slow
           Protocols, (3) a Slow Protocols subtype equal to that of the
           subtype reserved for OAM, and (4) an OAMPDU code equal to the
           OAM Information code. 
                                  
           Discontinuities of this counter can occur at re-initialization
           of the management system, and at other times as indicated by
           the value of the ifCounterDiscontinuityTime. "
     ::= { cienaCesOamStatsEntry 2 }

 cienaCesOamUniqueEventNotificationTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of unique Event OAMPDUs transmitted on
                                         this interface. Event notifications may be sent in duplicate
                                         to increase the probability of successfully being received,
                                         given the possibility that a frame may be lost in transit. 
                                  
                                         An Event Notification OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Event code. 
                                  
                                         A unique Event Notification OAMPDU is indicated as an Event
                                         Notification OAMPDU with a Sequence Number field that is
                                         distinct from the previously transmitted Event Notification
                                         OAMPDU Sequence Number. 
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
      ::= { cienaCesOamStatsEntry 3 }

 cienaCesOamUniqueEventNotificationRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of unique Event OAMPDUs received on
                                         this interface. Event notification OAMPDUs may be sent in
                                         duplicate to increase the probability of successfully being
                                         received, given the possibility that a frame may be lost in
                                         transit. 
                                  
                                         An Event Notification OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equals the
                                         OAM Event code. 
                                  
                                         A unique Event Notification OAMPDU is indicated as an Event
                                         Notification OAMPDU with a Sequence Number field that is
                                         distinct from the previously received Event Notification                
                                         OAMPDU Sequence Number.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
      ::= { cienaCesOamStatsEntry 4 }

 cienaCesOamLoopbackControlTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Loopback Control OAMPDUs transmitted
                                         on this interface. 
                                  
                                         An Loopback Control OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Loopback Control code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
                                       REFERENCE   "[802.3ah], 30.3.6.1.26."
      ::= { cienaCesOamStatsEntry 5 }

 cienaCesOamLoopbackControlRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Loopback Control OAMPDUs transmitted
                                         on this interface. 
                                  
                                         An Loopback Control OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Loopback Control code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
                                       REFERENCE   "[802.3ah], 30.3.6.1.27."
      ::= { cienaCesOamStatsEntry 6 }

 cienaCesOamVariableRequestTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Variable Request OAMPDUs transmitted
                                         on this interface.  
                                  
                                         An Variable Request OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Variable Request code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
                                       REFERENCE   "[802.3ah], 30.3.6.1.28."
      ::= { cienaCesOamStatsEntry 7 }

 cienaCesOamVariableRequestRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Variable Request OAMPDUs received on
                                         this interface.  
                                         An Variable Request OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Variable Request code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
     ::= { cienaCesOamStatsEntry 8 }

 cienaCesOamVariableResponseTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Variable Response OAMPDUs
                                         transmitted on this interface.  
                                  
                                         An Variable Response OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Variable Response code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 9 }

 cienaCesOamVariableResponseRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Variable Response OAMPDUs received
                                         on this interface.  
                                  
                                         An Variable Response OAMPDU is indicated by a valid frame with
                                         (1) destination MAC address equal to that of the reserved MAC      
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Variable Response code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 10 }

 cienaCesOamOrgSpecificTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Organization Specific OAMPDUs
                                         transmitted on this interface.  
                                  
                                         An Organization Specific OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Organization Specific code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 11 }

 cienaCesOamOrgSpecificRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of Organization Specific OAMPDUs
                                         received on this interface.  
                                  
                                         An Organization Specific OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Organization Specific code.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 12 }

 cienaCesOamUnsupportedCodesTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of OAMPDUs transmitted on this
                                         interface with an unsupported op-code.  
                                  
                                         An unsupported op-code OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         op-code for a function that is not supported by the device. 
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 13 }

 cienaCesOamUnsupportedCodesRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of OAMPDUs received on this interface
                                         with an unsupported op-code.  
                                  
                                         An unsupported op-code OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         opcode for a function that is not supported by the device.
                                         
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
      ::= { cienaCesOamStatsEntry 14 }

 cienaCesOamframesLostDueToOam OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of frames that were dropped by the OAM
                                         multiplexer. Since the OAM multiplexer has multiple inputs
                                         and a single output, there may be cases where frames are
                                         dropped due to transmit resource contention. This counter is
                                         incremented whenever a frame is dropped by the OAM layer.
                                         When this counter is incremented, no other counters in this
                                         MIB are incremented. 
                                                       
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
      ::= { cienaCesOamStatsEntry 15 }

 cienaCesOamStatsPort OBJECT-TYPE
      SYNTAX Integer32 (1..1000)
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
                                "An Ethernet port on the switch."
      ::= { cienaCesOamStatsEntry 16 }

 cienaCesOamDuplicateEventNotificationTx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of duplicate Event OAMPDUs transmitted
                                         on this interface. Event notification OAMPDUs may be sent in
                                         duplicate to increase the probability of successfully being
                                         received, given the possibility that a frame may be lost in
                                         transit.  
                                  
                                         An Event Notification OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equals to the
                                         OAM Event code. 
                                  
                                         A duplicate Event Notification OAMPDU is indicated as an Event
                                         Notification OAMPDU with a Sequence Number field that is
                                         identical to the previously transmitted Event Notification
                                         OAMPDU Sequence Number.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime."
      ::= { cienaCesOamStatsEntry 17 }

 cienaCesOamDuplicateEventNotificationRx OBJECT-TYPE
      SYNTAX Counter32
      UNITS "frames"
      MAX-ACCESS read-only
      STATUS current
      DESCRIPTION
                                "A count of the number of duplicate Event OAMPDUs received on
                                         this interface. Event notification OAMPDUs may be sent in
                                         duplicate to increase the probability of successfully being
                                         received, given the possibility that a frame may be lost in
                                         transit. 
                                  
                                         An Event Notification OAMPDU is indicated by a valid frame
                                         with (1) destination MAC address equal to that of the reserved
                                         MAC address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAMPDU code equal to the
                                         OAM Event code.  
                                  
                                         A duplicate Event Notification OAMPDU is indicated as an Event
                                         Notification OAMPDU with a Sequence Number field that is
                                         identical to the previously received Event Notification OAMPDU
                                         Sequence Number.  
                                  
                                         Discontinuities of this counter can occur at re-initialization
                                         of the management system, and at other times as indicated by
                                         the value of the ifCounterDiscontinuityTime. "
      ::= { cienaCesOamStatsEntry 18 }


 cienaCesOamEventLogTable   OBJECT-TYPE 
      SYNTAX       SEQUENCE OF CienaCesOamEventLogEntry 
      MAX-ACCESS   not-accessible 
      STATUS       current 
      DESCRIPTION 
                                "This table records a history of the events that have occurred
                                         at the Ethernet OAM level. These events can include locally
                                         detected events, which may result in locally generated
                                         OAMPDUs, and remotely detected events, which are detected by
                                         the OAM peer entity and signaled to the local entity via
                                         Ethernet OAM. Ethernet OAM events can be signaled by Event
                                         Notification OAMPDUs or by the flags field in any OAMPDU. "
 ::= { cienaCesOamStatistics 2 } 
  
 cienaCesOamEventLogEntry OBJECT-TYPE 
      SYNTAX      CienaCesOamEventLogEntry 
      MAX-ACCESS  not-accessible 
      STATUS      current 
      DESCRIPTION "An entry in the cienaCesOamEventLogTable." 
      INDEX       { cienaCesOamEventLogPort, cienaCesOamEventLogIndex }
 ::= { cienaCesOamEventLogTable 1 } 
  
 CienaCesOamEventLogEntry ::= SEQUENCE {
 cienaCesOamEventLogPort                 Integer32,
 cienaCesOamEventLogIndex                Unsigned32,
 cienaCesOamEventLogTimestamp            TimeStamp,
 cienaCesOamEventLogOui                  OCTET STRING, 
 cienaCesOamEventLogType                 INTEGER,
 cienaCesOamEventLogLocation             INTEGER,
 cienaCesOamEventLogWindowHi             Unsigned32,
 cienaCesOamEventLogWindowLo             Unsigned32,                                                              
 cienaCesOamEventLogThresholdHi          Unsigned32,
 cienaCesOamEventLogThresholdLo          Unsigned32,
 cienaCesOamEventLogValue                Counter64,
 cienaCesOamEventLogRunningTotal         Counter64,
 cienaCesOamEventLogEventTotal           Unsigned32,
 cienaCesOamEventNotifChassisIndex       Unsigned32,
 cienaCesOamEventNotifShelfIndex         Unsigned32,
 cienaCesOamEventNotifSlotIndex	         Unsigned32,
 cienaCesOamEventNotifPortNumber         Unsigned32,
 cienaCesOamEventNotifChannelNumber      Unsigned32
 }
        
 cienaCesOamEventLogPort OBJECT-TYPE
      SYNTAX Integer32
      MAX-ACCESS not-accessible
      STATUS current
      DESCRIPTION
                                                        "An Ethernet port on the switch."
 ::= { cienaCesOamEventLogEntry 1 }       
  
 cienaCesOamEventLogIndex       OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  not-accessible
     STATUS      current 
     DESCRIPTION 
                                "An arbitrary integer for identifying individual events
                                        within the event log. "
 ::= { cienaCesOamEventLogEntry 2 }
  
 cienaCesOamEventLogTimestamp  OBJECT-TYPE 
     SYNTAX      TimeStamp 
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                "The value of sysUpTime at the time of the logged event. For
                                         locally generated events, the time of the event can be
                                         accurately retrieved from sysUpTime. For remotely generated
                                         events, the time of the event is indicated by the reception of
                                         the Event Notification OAMPDU indicating the event occurred on
                                         the peer. A system may attempt to adjust the timestamp value
                                         to more accurately reflect the time of the event at the peer
                                         OAM entity by using other information, such as that found in
                                         the timestamp found on the Event Notification TLVs, which
                                         provides an indication of the relative time between events at
                                         the peer entity. "
 ::= { cienaCesOamEventLogEntry 3 }
  
 cienaCesOamEventLogOui  OBJECT-TYPE 
     SYNTAX      OCTET STRING(SIZE(3))
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                "The OUI of the entity defining the object type. All IEEE
                                         802.3 defined events (as appearing in [802.3ah] except for the
                                         Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
                                         0x0180C2. Organizations defining their own Event Notification
                                         TLVs include their OUI in the Event Notification TLV, which
                                         gets reflected here. "
 ::= { cienaCesOamEventLogEntry 4 }
  
 cienaCesOamEventLogType      OBJECT-TYPE
     SYNTAX      INTEGER
     					{
     						errFramePeriodEvent(1),
     						errFrameEvent(2),
     						errFrameSecSummEvent(3),
     						linkFaultEvent(4),
     						dyingGaspEvent(5),
     						criticalLinkEvent(6),
     						noEvent(99)
     					} 
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                "The type of event that generated this entry in the event log.
  
                                        When the OUI is the IEEE 802.3 OUI of 0x0180C2, the following
                                        event types are defined:
                                             erroredSymbolEvent(1), 
                                             erroredFramePeriodEvent (2), 
                                             erroredFrameEvent(3),
                                             erroredFrameSecondsEvent(4), 
                                             linkFault(256), 
                                             dyingGaspEvent(257),
                                             criticalLinkEvent(258)
                                         The first four are considered threshold crossing events as
                                         they are generated when a metric exceeds a given value within
                                         a specified window. The other three are not threshold
                                         crossing events. 
                                  
                                         When the OUI is not 0x0180C2, then some other organization has
                                         defined the event space. If event subtyping is known to the
                                         implementation, it may be reflected here. Otherwise, this
                                         value should return noEvent (99). 
                                         "
     REFERENCE   "[802.3ah], 30.3.6.1.10 and 57.5.3."
 ::= { cienaCesOamEventLogEntry 5 }
  
 cienaCesOamEventLogLocation OBJECT-TYPE 
     SYNTAX      INTEGER 
     					{
     					 local(1), 
     					 remote(2) 
     			}
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                "Whether this event occurred locally, or was received from the
                                        OAM peer via Ethernet OAM."
 ::= { cienaCesOamEventLogEntry 6 }
                                
 cienaCesOamEventLogWindowHi      OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                                "If the event represents a threshold crossing event, the two
                                                objects cienaCesOamEventWindowHi and cienaCesOamEventWindowLo form an
                                                unsigned 64-bit integer yielding the window over which the
                                                value was measured for the threshold crossing event (e.g., 5,
                                                when 11 occurrences happened in 5 seconds while the threshold
                                                was 10). The two objects are combined as:
                
                                                cienaCesOamEventLogWindow = ((2^32) * cienaCesOamEventLogWindowHi)
                                                + cienaCesOamEventLogWindowLo.
                                                Otherwise, this value is returned as all Fs (0xFFFFFFFF) and 
                                                adds no useful information. "
     REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 7 }     
               
 cienaCesOamEventLogWindowLo      OBJECT-TYPE
     SYNTAX      Unsigned32
     MAX-ACCESS  read-only
     STATUS      current 
     DESCRIPTION 
                                                "If the event represents a threshold crossing event, the two
                                                objects cienaCesOamEventWindowHi and cienaCesOamEventWindowLo form an
                                                unsigned 64-bit integer yielding the window over which the
                                                value was measured for the threshold crossing event (e.g., 5,
                                                when 11 occurrences happened in 5 seconds while the threshold
                                                was 10).  The two objects are combined as:
  
                                                cienaCesOamEventLogWindow = ((2^32) * cienaCesOamEventLogWindowHi)
                                                + cienaCesOamEventLogWindowLo.
  
                                                Otherwise, this value is returned as all Fs (0xFFFFFFFF) and 
                                                adds no useful information. "
     REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 8 }
     
 cienaCesOamEventLogThresholdHi      OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current 
      DESCRIPTION 
                                                        "If the event represents a threshold crossing event, the two
                                                        objects cienaCesOamEventThresholdHi and cienaCesOamEventThresholdLo 
                                                        form an unsigned 64-bit integer yielding the value that was
                                                        crossed for the threshold crossing event (e.g., 10, when 11 
                                                        occurrences happened in 5 seconds while the threshold was 10).
                                                        The two objects are combined as:
  
                                                        cienaCesOamEventLogThreshold = ((2^32) * cienaCesOamEventLogThresholdHi)
                                                        + cienaCesOamEventLogThresholdLo.
  
                                                        Otherwise, this value is returned as all Fs (0xFFFFFFFF) and 
                                                        adds no useful information. "
      REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 9 }
     
 cienaCesOamEventLogThresholdLo      OBJECT-TYPE
       SYNTAX      Unsigned32
       MAX-ACCESS  read-only
       STATUS      current 
       DESCRIPTION 
         "If the event represents a threshold crossing event, the two
         objects cienaCesOamEventThresholdHi and cienaCesOamEventThresholdLo 
         form an unsigned 64-bit integer yielding the value that was
         crossed for the threshold crossing event (e.g., 10, when 11 
         occurrences happened in 5 seconds while the threshold was 10).
         The two objects are combined as:
         cienaCesOamEventLogThreshold = ((2^32) * cienaCesOamEventLogThresholdHi) 
         + cienaCesOamEventLogThresholdLo.
  
         Otherwise, this value is returned as all Fs (0xFFFFFFFF) and
         adds no useful information. "
       REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 10 }
  
                
 cienaCesOamEventLogValue      OBJECT-TYPE
      SYNTAX      Counter64 
      MAX-ACCESS  read-only
      STATUS      current 
      DESCRIPTION 
                                "If the event represents a threshold crossing event, this
                                         value indicates the value of the parameter within the given
                                         window that generated this event (e.g., 11, when 11 occurrences
                                         happened in 5 seconds while the threshold was 10). 
                                  
                                         Otherwise, this value is returned as all F's 
                                         (0xFFFFFFFFFFFFFFFF) and adds no useful information. 
                                         "
      REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 11 }
  
 cienaCesOamEventLogRunningTotal      OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current 
      DESCRIPTION 
                                "This value represents the total number of times this
                                         occurrence has happened since the last reset (e.g., 3253, when
                                         3253 symbol errors have occurred since the last reset, which
                                         has resulted in 51 symbol error threshold crossing events
                                         since the last reset). "
      REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 12 }
  
 cienaCesOamEventLogEventTotal      OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current 
      DESCRIPTION 
                                "This value represents the total number of times one or more
                                         of these occurrences have resulted in an event (e.g., 51 when
                                         3253 symbol errors have occurred since the last reset, which
                                         has resulted in 51 symbol error threshold crossing events
                                         since the last reset)."
      REFERENCE   "[802.3ah], 30.3.6.1.37 and 57.5.3.2."
 ::= { cienaCesOamEventLogEntry 13 }

 cienaCesOamEventNotifChassisIndex          OBJECT-TYPE
     SYNTAX          Unsigned32 (1..1)
     MAX-ACCESS      accessible-for-notify
     STATUS          current
     DESCRIPTION
           "This object indicates the chassis index for the port used for trap definition."               
     ::= { cienaCesOamEventLogEntry 14 }
     
 cienaCesOamEventNotifShelfIndex          OBJECT-TYPE
     SYNTAX          Unsigned32 (1..1)
     MAX-ACCESS      accessible-for-notify
     STATUS          current
     DESCRIPTION
           "This object indicates the shelf index for the port used for trap definition."               
     ::= { cienaCesOamEventLogEntry 15 }

 cienaCesOamEventNotifSlotIndex          OBJECT-TYPE
     SYNTAX          Unsigned32 (1..7)
     MAX-ACCESS      accessible-for-notify
     STATUS          current
     DESCRIPTION
           "This object indicates the slot index for the port used for trap definition."
     ::= { cienaCesOamEventLogEntry 16 }

 cienaCesOamEventNotifPortNumber		OBJECT-TYPE
 	SYNTAX			Unsigned32(1..65535)
 	MAX-ACCESS		accessible-for-notify
 	STATUS			current
 	DESCRIPTION
 		"This object indicates the port number for the corresponding PGID
 		used for trap definition."
 	::= { cienaCesOamEventLogEntry 17 }

 cienaCesOamEventNotifChannelNumber		OBJECT-TYPE
 	SYNTAX			Unsigned32
  	MAX-ACCESS		accessible-for-notify
  	STATUS			current
  	DESCRIPTION
  		"This object indicates the channel number for the corresponding PGID
  		used for trap definition. The value 0 is used if port of concern is
  		not channelized."
  	::= { cienaCesOamEventLogEntry 18 }
                        
 
 cienaCesOamStatsClear      OBJECT-TYPE
      SYNTAX      CienaStatsClear
      MAX-ACCESS  read-write
      STATUS      current 
      DESCRIPTION           
                    "Setting this object to 'true' causes the values of all objects maintained 
                     within the cienaCesOamStatsTable to reset to the value of zero. 
                     When read, this object always returns the value of false."
 ::= { cienaCesOamStatistics 3 }


  cienaCesOamTable OBJECT-TYPE
       SYNTAX SEQUENCE OF CienaCesOamEntry
       MAX-ACCESS not-accessible
       STATUS current
       DESCRIPTION
                      "Primary controls and status for the OAM capabilities of an
                       Ethernet like interface.  There is one row in this table
                       for each Ethernet like interface in the system that supports
                       the Ethernet OAM functions defined in [802.3ah]."
  ::= { cienaCesOamStatistics 4 }

                
  cienaCesOamEntry OBJECT-TYPE
        SYNTAX CienaCesOamEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION
                       "An entry in the table. Contains an Ethernet like interface
              		in the system that supports the Ethernet OAM functions
              		defined in [802.3ah]."
        INDEX { cienaCesOamPort }
                ::= { cienaCesOamTable 1 }

                
  CienaCesOamEntry ::=
                        SEQUENCE { 
                                cienaCesOamPort
                                        Integer32,
				cienaCesOamAdminState
                                        INTEGER,
                                cienaCesOamOperStatus
                                        INTEGER,
                                cienaCesOamMode
                                        INTEGER,
                                cienaCesMaxOamPduSize
                                        Integer32,
                                cienaCesOamConfigRevision
                                        Unsigned32,
                                cienaCesOamFunctionsSupported
                                        BITS,
                                cienaCesOamPduTimer
                                		INTEGER,
                                cienaCesOamLinkLostTimer
                                		INTEGER
                         }

                cienaCesOamPort OBJECT-TYPE
                        SYNTAX Integer32
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "An Ethernet port on the switch."
                        ::= { cienaCesOamEntry 1 }

                cienaCesOamAdminState OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                disabled(1),
                                enabled(2)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "This object is used to provision the default administrative OAM mode for this 
                                interface.  This object represents the desired state of OAM for this interface.  
                                  
                                The cienaCesOamAdminState always starts in the disabled(1) state
                                         until an explicit management action or configuration
                                         information retained by the system causes a transition to the
                                         enabled(2) state. 
                                  
                                         Note that the value of this object is ignored when the
                                         interface is not operating in full-duplex mode. OAM is not
                                         supported on half-duplex links."
                        ::= { cienaCesOamEntry 2 }

                
                cienaCesOamOperStatus OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                disabled(1),
                                linkfault(2),
                                passiveWait(3),
                                activeSendLocal(4),
                                sendLocalAndRemote(5),
                                sendLocalAndRemoteOk(6),
                                oamPeeringLocallyRejected(7),
                                oamPeeringRemotelyRejected(8),
                                operational(9)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "At initialization and failure conditions, two OAM entities on
                                         the same full-duplex Ethernet link begin a discovery phase to
                                         determine what OAM capabilities may be used on that link.  The
                                         progress of this initialization is controlled by the OAM
                                         sub layer.  
                                                    
                                         This value is always disabled(1) if OAM is disabled on this
                                         interface via the cienaCesOamAdminState.  
                                  
                                         If the link has detected a fault and is transmitting OAMPDUs
                                         with a link fault indication, the value is linkFault(2). 
                                                          
                                         The passiveWait(3) state is returned only by OAM entities in
                                         passive mode (cienaCesOamMode) and reflects the state in which the
                                         OAM entity is waiting to see if the peer device is OAM
                                         capable.  The activeSendLocal(4) is used by active mode
                                         devices (cienaCesOamMode) and reflects the OAM entity actively
                                         trying to discover whether the peer has OAM capability but has
                                         not yet made that determination.
                                                          
                                         The state sendLocalAndRemote(5) indicates that the local OAM
                                         entity has discovered the peer but has not yet accepted or
                                         rejected the configuration of the peer.  The local device can,
                                         for whatever reason, decide that the peer device is
                                         unacceptable and decline OAM peering.  If the local OAM entity
                                         rejects the peer OAM entity, the state becomes
                                         oamPeeringLocallyRejected(7).  If the OAM peering is allowed
                                         by the local device, the state moves to
                                         sendLocalAndRemoteOk(6).  Note that both the
                                         sendLocalAndRemote(5) and oamPeeringLocallyRejected(7) states
                                         fall within the state SEND_LOCAL_REMOTE of the Discovery state
                                         diagram [802.3ah, Figure 57-5], with the difference being
                                         whether the local OAM client has actively rejected the peering
                                         or has just not indicated any decision yet.  Whether a peering
                                         decision has been made is indicated via the local flags field
                                         in the OAMPDU (reflected in the aOAMLocalFlagsField of
                                         30.3.6.1.10).  
                                  
                                         If the remote OAM entity rejects the peering, the state
                                         becomes oamPeeringRemotelyRejected(8).  Note that both the
                                         sendLocalAndRemoteOk(6) and oamPeeringRemotelyRejected(8)
                                         states fall within the state SEND_LOCAL_REMOTE_OK of the
                                         Discovery state diagram [802.3ah, Figure 57-5], with the
                                         difference being whether the remote OAM client has rejected
                                         the peering or has just not yet decided.  This is indicated
                                         via the remote flags field in the OAM PDU (reflected in the
                                         aOAMRemoteFlagsField of 30.3.6.1.11).  
                                                          
                                         When the local OAM entity learns that both it and the remote
                                         OAM entity have accepted the peering, the state moves to
                                         operational(9) corresponding to the SEND_ANY state of the
                                         Discovery state diagram [802.3ah, Figure 57-5]."
                        ::= { cienaCesOamEntry 3 }

                
                cienaCesOamMode OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                active(1),
                                passive(2)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "This object indicates the mode of OAM operation for this
                                         Ethernet like interface.  OAM on Ethernet interfaces may be in
                                         'active' mode or 'passive' mode.  These two modes differ in
                                         that active mode provides additional capabilities to initiate
                                         monitoring activities with the remote OAM peer entity, while
                                         passive mode generally waits for the peer to initiate OAM
                                         actions with it.  As an example, an active OAM entity can put
                                         the remote OAM entity in a loopback state, where a passive OAM
                                         entity cannot.  
                                  
                                         The default value of cienaCesOamMode is dependent on the type of
                                         system on which this Ethernet like interface resides.  The
                                         default value should be 'active(1)' unless it is known that
                                         this system should take on a subservient role to the other
                                         device connected over this interface.  
                                  
                                         If this values gets changed it value results in incrementing the 
					 configuration revision field of locally generated OAMPDUs (30.3.6.1.12) 
	                                 and potentially re-doing the OAM discovery process if the
                                         cienaCesOamOperStatus was already operational(9)."
                        ::= { cienaCesOamEntry 4 }

                
                cienaCesMaxOamPduSize OBJECT-TYPE
                        SYNTAX Integer32
                        UNITS "bytes"
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The largest OAMPDU that the OAM entity supports.  OAM
                                         entities exchange maximum OAMPDU sizes and negotiate to use
                                         the smaller of the two maximum OAMPDU sizes between the peers.
                                         This value is determined by the local implementation."
                        ::= { cienaCesOamEntry 5 }

                
                cienaCesOamConfigRevision OBJECT-TYPE
                        SYNTAX Unsigned32
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The configuration revision of the OAM entity as reflected in
                                         the latest OAMPDU sent by the OAM entity.  The configuration revision
                                         is used by OAM entities to indicate configuration changes have
                                         occurred which might require the peer OAM entity to re-evaluate
                                         whether the peering is allowed.  See local_satisfied in
                                         [802.3ah, 57.3.1.2]."
                        ::= { cienaCesOamEntry 6 }

                
                cienaCesOamFunctionsSupported OBJECT-TYPE
                        SYNTAX BITS
                                {
                                unidirectionalSupport(0),
                                loopbackSupport(1),
                                eventSupport(2),
                                variableSupport(3)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The OAM functions supported on this Ethernet like interface.
                                         OAM consists of separate functional sets beyond the basic
                                         discovery process which is always required.  These functional
                                         groups can be supported independently by any implementation.
                                         These values are communicated to the peer via the local
                                         configuration field of Information OAMPDUs."
                        ::= { cienaCesOamEntry 7 }


                cienaCesOamPduTimer OBJECT-TYPE
                        SYNTAX INTEGER (100..1000)
                        UNITS "milliseconds"
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The time in milliseconds between Information OAMPDUs
                                being transmitted via the Ethernet port."
                        ::= { cienaCesOamEntry 8 }

                cienaCesOamLinkLostTimer OBJECT-TYPE
                        SYNTAX INTEGER (500..5000)
                        UNITS "milliseconds"
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The time in milliseconds to wait for an Information OAMPDU
                                via the Ethernet port, from a peer, before declaring the link lost."
                        ::= { cienaCesOamEntry 9 }

                cienaCesOamPeerTable OBJECT-TYPE
                        SYNTAX SEQUENCE OF CienaCesOamPeerEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "Information about the OAM peer for a particular Ethernet like
                                         interface. OAM entities communicate with a single OAM peer
                                         entity on full-duplex Ethernet links on which OAM is enabled
                                         and operating properly.  
                                         
                                         In certain states, the OAM peer information is not available.
                                         Whether peer information is available is communicated via the
                                         cienaCesOamPeerStatus object.  When this object is inactive, all
                                         other information in the row is considered invalid."
                        ::= { cienaCesOamStatistics 5 }

                
                cienaCesOamPeerEntry OBJECT-TYPE
                        SYNTAX CienaCesOamPeerEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "An entry in the table, containing information on the peer OAM
                                         entity for a single Ethernet like interface.  
                                  
                                         Note that there is at most one OAM peer for each Ethernet like
                                         interface.  There is exactly one row in this table for each
                                         Ethernet like interface supporting OAM."
                        INDEX { cienaCesOamLocalPort }
                        ::= { cienaCesOamPeerTable 1 }

                
                CienaCesOamPeerEntry ::=
                        SEQUENCE {                              
                                cienaCesOamLocalPort                                     Integer32,
                                cienaCesOamPeerStatus                                    INTEGER,
                                cienaCesOamPeerMacAddress                                OCTET STRING,
                                cienaCesOamPeerVendorOui                                 OCTET STRING,
                                cienaCesOamPeerVendorInfo                                Unsigned32,
                                cienaCesOamPeerMode                                      INTEGER,
                                cienaCesOamPeerMaxOamPduSize                             Integer32,
                                cienaCesOamPeerConfigRevision                            Unsigned32,
                                cienaCesOamPeerFunctionsSupported                        BITS
                         }

                cienaCesOamLocalPort OBJECT-TYPE
                        SYNTAX Integer32 
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "An Ethernet port on the local switch."
                        ::= { cienaCesOamPeerEntry 1 }

                cienaCesOamPeerStatus OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                active(1),
                                inactive(2)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "This object indicates whether the information in this row
                                         should be considered valid.  When active(1), the information
                                         is valid and represents the current peer of the OAM entity.
                                         When inactive(2), the information in this row is invalid.  
                                  
                                         A value of inactive(2) is returned if the cienaCesOamOperStatus is
                                         disabled, passiveWait, or activeSendLocal.  For all other
                                         values of cienaCesOamOperStatus, a value of active(1) is returned."
                        ::= { cienaCesOamPeerEntry 2 }

                
                cienaCesOamPeerMacAddress OBJECT-TYPE
                        SYNTAX OCTET STRING(SIZE(6))
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The MAC address of the peer OAM entity.  The MAC address is
                                         derived from the most recently received OAMPDU.  This value is
                                         initialized to all zeros (0x000000000000).  This value is
                                         invalid if the cienaCesOamPeerStatus is inactive.  
                                  
                                         An OAMPDU is indicated by a valid frame with (1) destination
                                         MAC address equal to that of the reserved MAC address for Slow
                                         Protocols (See 43B of [802.3ah]), (2) a lengthOrType field
                                         equal to the reserved type for Slow Protocols, (3) and a Slow
                                         Protocols subtype equal to that of the subtype reserved for
                                         OAM."
                        ::= { cienaCesOamPeerEntry 3 }

                
                cienaCesOamPeerVendorOui OBJECT-TYPE
                        SYNTAX OCTET STRING(SIZE(3))
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The OUI of the OAM peer as reflected in the latest
                                         Information OAMPDU received with a Local Information TLV.  The
                                         OUI can be used to identify the vendor of the remote OAM
                                         entity.  This value is initialized to all zeros (0x000000).
                                         This value is considered invalid if the cienaCesOamPeerStatus is
                                         inactive.  
                                  
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow Protocols, (3) 
	                                 a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the code
                                         reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 4 }

                
                cienaCesOamPeerVendorInfo OBJECT-TYPE
                        SYNTAX Unsigned32
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The Vendor Info of the OAM peer as reflected in the latest
                                         Information OAMPDU received with a Local Information TLV.  The
                                         vendor information field is within the Local Information TLV,
                                         and can be used to determine additional information about the
                                         peer entity.  The format of the vendor information is
                                         unspecified within the 32-bit field.  This value is initialized
                                         to all zero.  This value is invalid if the cienaCesOamPeerStatus 
					 is inactive.  
                                  
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the
                                         code reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 5 }

                
                cienaCesOamPeerMode OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                active(1),
                                passive(2),
                                unknown(3)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The mode of the OAM peer as reflected in the latest
                                         Information OAMPDU received with a Local Information TLV.  The
                                         mode of the peer can be determined from the Configuration
                                         field in the Local Information TLV of the last Information
                                         OAMPDU received from the peer.  This value is initialized to
                                         unknown(3), and is not valid if the cienaCesOamPeerStatus is
                                         inactive.  
                                  
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the
                                         code reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 6 }

                
                cienaCesOamPeerMaxOamPduSize OBJECT-TYPE
                        SYNTAX Integer32
                        UNITS "bytes"
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The maximum size of OAMPDU supported by the peer as reflected
                                         in the latest Information OAMPDU received with a Local
                                         Information TLV.   Ethernet OAM on this interface must not use
                                         OAMPDUs that exceed this size.  The maximum OAMPDU size can be
                                         determined from the PDU Configuration field of the Local
                                         Information TLV of the last Information OAMPDU received from
                                         the peer.  This value is initialized to 64, and is invalid if
                                         the cienaCesOamPeerStatus is inactive.
                                  
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the
                                         code reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 7 }

                
                cienaCesOamPeerConfigRevision OBJECT-TYPE
                        SYNTAX Unsigned32
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The configuration revision of the OAM peer as reflected in
                                         the latest OAMPDU.  This attribute is changed by the peer
                                         whenever it has a local configuration change for Ethernet OAM
                                         this interface.  This value is initialized to zero, 
					 and is invalid if the cienaCesOamPeerStatus is
                                         inactive.
                                  
                                         The configuration revision can be determined from the Revision
                                         field of the Local Information TLV of the most recently
                                         received Information OAMPDU with a Local Information TLV.
                                                         
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the
                                         code reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 8 }

                
                cienaCesOamPeerFunctionsSupported OBJECT-TYPE
                        SYNTAX BITS
                                {
                                unidirectionalSupport(0),
                                loopbackSupport(1),
                                eventSupport(2),
                                variableSupport(3)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The OAM functions supported on this Ethernet like interface.
                                         OAM consists of separate functionality sets above the basic
                                         discovery process.  This value indicates the capabilities of
                                         the peer OAM entity with respect to these functions.  This
                                         value is initialized so all bits are clear, and is invalid if
                                         the cienaCesOamPeerStatus is inactive.
                                  
                                         The capbilities of the OAM peer can be determined from the
                                         configuration field of the Local Information TLV of the most
                                         recently received Information OAMPDU with a Local Information
                                         TLV.
                                                         
                                         An Information OAMPDU is indicated by a valid frame with (1)
                                         destination MAC address equal to that of the reserved MAC
                                         address for Slow Protocols (See 43B of [802.3ah]), (2) a
                                         lengthOrType field equal to the reserved type for Slow
                                         Protocols, (3) a Slow Protocols subtype equal to that of the
                                         subtype reserved for OAM, and (4) an OAM code that equals the
                                         code reserved for Information OAMPDUs."
                        ::= { cienaCesOamPeerEntry 9 }


                
                cienaCesOamLoopbackTable OBJECT-TYPE
                        SYNTAX SEQUENCE OF CienaCesOamLoopbackEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "This table contains methods to control the loopback state of
                                 the local link as well as indicating the status of the
                                 loopback function.
                                  
                                 Loopback can be used to place the remote OAM entity in a state
                                 where every received frame (except OAMPDUs) are echoed back
                                 over the same interface on which they were received.   In this
                                 state, at the remote entity, 'normal' traffic is disabled as
                                 only the looped back frames are transmitted on the interface.
                                 Loopback is thus an intrusive operation that prohibits normal
                                 data flow and should be used accordingly."
                        ::= { cienaCesOamStatistics 6 }

                
                cienaCesOamLoopbackEntry OBJECT-TYPE
                        SYNTAX CienaCesOamLoopbackEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "An entry in the table, containing information on the loopback
                                         status for a single Ethernet like interface.  There is an
                                         entry in this table for every Ethernet like interface which
                                         supports OAM and loopback function within OAM (as indicated in
                                         cienaCesOamFunctionsSupported)."
                        INDEX { cienaCesOamLoopbackPort }
                        ::= { cienaCesOamLoopbackTable 1 }

                
                CienaCesOamLoopbackEntry ::=
                        SEQUENCE { 
                                cienaCesOamLoopbackPort
                                        Integer32,
                                cienaCesOamLoopbackCommand
                                        INTEGER,
                                cienaCesOamLoopbackStatus
                                        INTEGER,
                                cienaCesOamLoopbackIgnoreRx
                                        INTEGER
                         }

                cienaCesOamLoopbackPort OBJECT-TYPE
                        SYNTAX Integer32 
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "An Ethernet port on the switch."
                        ::= { cienaCesOamLoopbackEntry 1 }

                cienaCesOamLoopbackCommand OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                noLoopback(1),
                                startRemoteLoopback(2),
                                stopRemoteLoopback(3)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "This attribute initiates or terminates remote loopback with
                                         an OAM peer.  Value startRemoteLoopback(2) of this attribute
                                         indicates the local OAM client to send a loopback OAMPDU to the
                                         OAM peer with the loopback enable flags set.  Value
                                         stopRemoteLoopback(3) of this attribute indicates the local
                                         OAM client to send a loopback OAMPDU to the OAM peer with the
                                         loopback enable flags cleared.  Value noLoopback(1) to this
                                         attribute has no effect.  
                                  
                                         The attribute always returns noLoopback on a read.  To
                                         determine the loopback status, use the attribute
                                         cienaCesOamLoopbackStatus."
                        ::= { cienaCesOamLoopbackEntry 2 }

                
                cienaCesOamLoopbackStatus OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                noLoopback(1),
                                initiatingLoopback(2),
                                remoteLoopback(3),
                                terminatingLoopback(4),
                                localLoopback(5),
                                unknown(6)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "The loopback status of the OAM entity.  This status is
                                         determined by a combination of the local parser and
                                         multiplexer states, the remote parser and multiplexer states,
                                         as well as by the actions of the local OAM client.  When
                                         operating in normal mode with no loopback in progress, the
                                         status reads noLoopback(1).  
                                                         
                                         If the OAM client has sent a Loopback OAMPDU and is waiting
                                         for a response, where the local parser and multiplexer states
                                         are DISCARD (see [802.3ah, 57.2.11.1]), the status is
                                         'initiatingLoopback'.  In this case, the local OAM entity has
                                         yet to receive any acknowledgement that the remote OAM entity
                                         has received its loopback command request.  
                                                         
                                         If the local OAM client knows that the remote OAM entity is in
                                         loopback mode (via the remote state information as described
                                         in [802.3ah, 57.2.11.1, 30.3.6.1.15]), the status is remoteLoopback(3).  
					 If the local OAM client is in the process
                                         of terminating the remote loopback [802.3ah, 57.2.11.3,
                                         30.3.6.1.14], with its local multiplexer and parser states in
                                         DISCARD, the status is terminatingLoopback(4).  If the remote
                                         OAM client has put the local OAM entity in loopback mode as
                                         indicated by its local parser state, the status is
                                         localLoopback(5).  
                                  
                                         The unknown(6) status indicates the parser and multiplexer
                                         combination is unexpected.  This status may be returned if the
                                         OAM loopback is in a transition state but should not persist. 
                                  
                                         The values of this attribute correspond to the following
                                         values of the local and remote parser and multiplexer states. 
                                  
                                                            LclPrsr   LclMux    RmtPrsr   RmtMux
                                           noLoopback         FWD       FWD       FWD       FWD  
                                           initLoopback     DISCARD   DISCARD     FWD       FWD 
                                           rmtLoopback      DISCARD     FWD      LPBK    DISCARD
                                           tmtngLoopback    DISCARD   DISCARD    LPBK    DISCARD
                                           lclLoopback        LPBK    DISCARD   DISCARD     FWD
                                           unknown            ***   any other combination   ***"
                        ::= { cienaCesOamLoopbackEntry 3 }

                
                cienaCesOamLoopbackIgnoreRx OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                ignore(1),
                                process(2)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "Since OAM loopback is a disruptive operation (user traffic
                                         does not pass), this attribute provides a mechanism to provide
                                         controls over whether received OAM loopback commands are
                                         processed or ignored.  When the value is ignore(1), received
                                         loopback commands are ignored.  When the value is process(2),
                                         OAM loopback commands are processed.  The default value is to
                                         ignore loopback commands (ignore(1)).  
                                  
                                         The attribute has no meaning if the local OAM entity does not
                                         support the loopback function (as defined in
                                         cienaCesOamFunctionsSupported)."
                        ::= { cienaCesOamLoopbackEntry 4 }



                cienaCesOamSystemEnableDisable OBJECT-TYPE
                        SYNTAX INTEGER
                                {
                                enable(1),
                                disable(2)
                                }
                        MAX-ACCESS read-only
                        STATUS current
                        DESCRIPTION
                                "This object indicates the administratively configurable state of the 
				OAM on the switch."
                        ::= { cienaCesOamStatistics 7 }

                
                cienaCesOamEventConfigTable OBJECT-TYPE  
                        SYNTAX SEQUENCE OF CienaCesOamEventConfigEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                                "Ethernet OAM includes the ability to generate and receive
                                 event notifications to indicate various link problems.  This
                                 table contains the mechanisms to configure the thresholds to
                                 generate the standard Ethernet OAM Event.
                                 These events are:
                                    - Errored Symbol Period Event.  Generated when the number of
                                      symbol errors exceeds a threshold within a given window
                                      defined by a number of symbols (e.g. 1,000 symbols out of
                                      1,000,000 had errors).
                                    - Errored Frame Period Event.  Generated when the number of
                                      frame errors exceeds a threshold within a given window
                                      defined by a number of frames (e.g. 10 frames out of 1000
                                      had errors).
                                    - Errored Frame Event.  Generated when the number of frame
                                      errors exceeds a threshold within a given window defined
                                      by a period of time (e.g. 10 frames in 1 second had
                                      errors).
                                    - Errored Frame Seconds Summary Event.  Generated when the
                                      number of errored frame seconds exceeds a threshold within
                                      a given time period (e.g. 10 errored frame seconds within
                                      the last 100 seconds).  An errored frame second is defined
                                      as a 1 second interval that had >0 frame errors."   
                        ::= { cienaCesOamStatistics 8 }
  
                cienaCesOamEventConfigEntry OBJECT-TYPE
                        SYNTAX CienaCesOamEventConfigEntry
                        MAX-ACCESS not-accessible
                        STATUS current
                        DESCRIPTION
                               "Event configuration information is available for every
                                Ethernet like interface that supports OAM and the event
                                function of OAM as indicated in the cienaCesOamFunctionsSupported
                                attribute.  
                                           
                                Event configuration controls when the local management entity
                                sends Event Notification OAMPDUs to its OAM peer."
                  
                        INDEX { cienaCesOamEventPort }
                        ::= { cienaCesOamEventConfigTable 1 }
                
                CienaCesOamEventConfigEntry ::=
                        SEQUENCE { 
                                cienaCesOamEventPort                               Integer32,
                                cienaCesOamErrFramePeriodWindow                    Unsigned32,
                                cienaCesOamErrFramePeriodThreshold                 Unsigned32,
                                cienaCesOamErrFramePeriodEvNotifEnable             INTEGER,
                                cienaCesOamErrFrameWindow                          Unsigned32,             
                                cienaCesOamErrFrameThreshold                       Unsigned32,
                                cienaCesOamErrFrameEvNotifEnable                   INTEGER,
                                cienaCesOamErrFrameSecsSummaryWindow               Integer32,
                                cienaCesOamErrFrameSecsSummaryThreshold            Integer32,
                                cienaCesOamErrFrameSecsEvNotifEnable               INTEGER,
                                cienaCesOamDyingGaspEnable                         INTEGER,
                                cienaCesOamCriticalEventEnable                     INTEGER
                                        }
        
                cienaCesOamEventPort OBJECT-TYPE
                    SYNTAX Integer32
                    MAX-ACCESS not-accessible
                    STATUS current
                    DESCRIPTION
                           "An Ethernet port on the switch"
                       ::= { cienaCesOamEventConfigEntry 1 }


                cienaCesOamErrFramePeriodWindow OBJECT-TYPE
                    SYNTAX      Unsigned32
                    UNITS       "frames"
                    MAX-ACCESS  read-only
                    STATUS      current
                    DESCRIPTION 
                                "The number of frames over which the threshold is defined. 
                                 The default value of the window is the number of minimum size
                                 Ethernet frames that can be received over the physical layer in
                                 one second.  
                                                 
                                 If cienaCesOamErrFramePeriodThreshold frame errors occur within a 
                                 window of cienaCesOamErrFramePeriodWindow frames, an Event
                                 Notification OAMPDU should be generated with an Errored Frame
                                 Period Event TLV indicating the threshold has been crossed in
                                 this window. 
                                 
                                 +------------ Range of errd-frame-period-window values------------+
                                 |         10    mbps link   : 1488    - 892800                    |
                                 |         100   mbps link   : 14880   - 8928000                   |
                                 |         1000  mbps link   : 148810  - 89285760                  |
                                 |         10000 mbps link   : 1488096 - 892857120                 |
                                 +-----------------------------------------------------------------+
                                 "
                       REFERENCE   "[802.3ah], 30.3.6.1.38"  
                       ::= { cienaCesOamEventConfigEntry 2 }

                 cienaCesOamErrFramePeriodThreshold OBJECT-TYPE
                        SYNTAX      Unsigned32 (0..4294967293)
                        UNITS       "frames"
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                              "The number of frame errors that must occur for this event to
                               be triggered.  The default value is one frame error.  
                                                         
                               If cienaCesOamErrFramePeriodThreshold frame errors occur within a
                               window of cienaCesOamErrFramePeriodWindow frames, an Event
                               Notification OAMPDU should be generated with an Errored Frame
                               Period Event TLV indicating the threshold has been crossed in
                               this window."
                        REFERENCE   "[802.3ah], 30.3.6.1.38"  
                        ::= { cienaCesOamEventConfigEntry 3 }
                       
                cienaCesOamErrFramePeriodEvNotifEnable OBJECT-TYPE 
                        SYNTAX      INTEGER 
                                    { 
				        enabled(1), 
					disabled(2) 
				    }
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "Indicates whether the occurrence of an Errored Frame Period
                                 Event should result in an Event Notification OAMPDU generated
                                 by the OAM layer.  
                                                         
                                 By default, this object should have the value enabled(1) for
                                 Ethernet like interfaces that support OAM.  If the OAM layer
                                 does not support event notifications (as indicated via the
                                 cienaCesOamFunctionsSupported attribute), this value is ignored."
                        ::= { cienaCesOamEventConfigEntry 4 }
                        
                cienaCesOamErrFrameWindow OBJECT-TYPE
                        SYNTAX      Unsigned32 (10..600)
                        UNITS       "tenths of a second"
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "The amount of time (in 100ms increments) over which the
                                 threshold is defined.  The default value is 10 (1 second).
                                                        
                                 If cienaCesOamErrFrameThreshold frame errors occur within a window
                                 of cienaCesOamErrFrameWindow seconds (measured in tenths of
                                 seconds), an Event Notification OAMPDU should be generated with
                                 an Errored Frame Event TLV indicating the threshold has been
                                 crossed in this window."
                        REFERENCE   "[802.3ah], 30.3.6.1.36"  
                        ::= { cienaCesOamEventConfigEntry 5 }
                       
                 cienaCesOamErrFrameThreshold OBJECT-TYPE
                        SYNTAX      Unsigned32 (0..4294967293)
                        UNITS       "frames"
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "The number of frame errors that must occur for this event to
                                 be triggered.  The default value is one frame error.  
                                                        
                                 If cienaCesOamErrFrameThreshold frame errors occur within a window
                                 of cienaCesOamErrFrameWindow (in tenths of seconds), an Event
                                 Notification OAMPDU should be generated with an Errored Frame
                                 Event TLV indicating the threshold has been crossed in this
                                 window."
                        REFERENCE   "[802.3ah], 30.3.6.1.36"  
                        ::= { cienaCesOamEventConfigEntry 6 }
                       
                cienaCesOamErrFrameEvNotifEnable OBJECT-TYPE 
                        SYNTAX      INTEGER 
                                    { 
				        enabled(1), 
					disabled(2) 
				    }
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "Indicates whether the occurrence of an Errored Frame Event
                                         should result in an Event Notification OAMPDU generated by the
                                         OAM layer.
                                                         
                                         By default, this object should have the value enabled(1) for
                                         Ethernet like interfaces that support OAM.  If the OAM layer
                                         does not support event notifications (as indicated via the
                                         cienaCesOamFunctionsSupported attribute), this value is ignored."
                        ::= { cienaCesOamEventConfigEntry 7 }
                          
                cienaCesOamErrFrameSecsSummaryWindow OBJECT-TYPE
                        SYNTAX      Integer32 (100..9000)
                        UNITS       "tenths of a second"
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "The amount of time (in 100ms intervals) over which the
                                         threshold is defined.  The default value is 100 (10 seconds).
                                                         
                                         If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
                                         within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
                                         of seconds), an Event Notification OAMPDU should be generated
                                         with an Errored Frame Seconds Summary Event TLV indicating the
                                         threshold has been crossed in this window."
                        REFERENCE   "[802.3ah], 30.3.6.1.40"  
                        ::= { cienaCesOamEventConfigEntry 8 }
                
                cienaCesOamErrFrameSecsSummaryThreshold OBJECT-TYPE
                        SYNTAX      Integer32 (0..65535)
                        UNITS       "errored frame seconds"
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "The number of errored frame seconds that must occur for this
                                         event to be triggered.  The default value is one errored frame
                                         second.
                                                         
                                         If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
                                         within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
                                         of seconds), an Event Notification OAMPDU should be generated
                                         with an Errored Frame Seconds Summary Event TLV indicating the
                                         threshold has been crossed in this window."
                        REFERENCE   "[802.3ah], 30.3.6.1.40"  
                        ::= { cienaCesOamEventConfigEntry 9 }
                       
                cienaCesOamErrFrameSecsEvNotifEnable OBJECT-TYPE 
                        SYNTAX      INTEGER 
                                    { 
				       enabled(1), 
				       disabled(2) 
				    }
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "Indicates whether the occurrence of an Errored Frame Seconds
                                         Summary Event should result in an Event Notification OAMPDU
                                         generated by the OAM layer.
                                                         
                                         By default, this object should have the value enabled(1) for
                                         Ethernet like interfaces that support OAM.  If the OAM layer
                                         does not support event notifications (as indicated via the
                                         cienaCesOamFunctionsSupported attribute), this value is ignored."
                        ::= { cienaCesOamEventConfigEntry 10 }
                       
                cienaCesOamDyingGaspEnable OBJECT-TYPE 
                        SYNTAX      INTEGER 
                                    { 
				        enabled(1), 
					disabled(2) 
				    }
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "Indicates whether the local device should attempt to indicate
                                         a dying gasp fault via the OAMPDU flags field to its peer OAM
                                         entity.  If the system does not support dying gasp capability,
                                         reading the object should always result in 'disabled(2)'.
                                         
                                         By default, this object should have the value enabled(1) for
                                         Ethernet like interfaces that support OAM.  If the OAM layer
                                         does not support event notifications (as indicated via the
                                         OamFunctionsSupported attribute), this value is ignored."
                        ::= { cienaCesOamEventConfigEntry 11 }
                 

                cienaCesOamCriticalEventEnable OBJECT-TYPE 
                        SYNTAX      INTEGER 
                                    { 
				       enabled(1), 
				       disabled(2) 
				    }
                        MAX-ACCESS  read-only
                        STATUS      current
                        DESCRIPTION 
                                "Indicates whether the local device should attempt to indicate
                                         a critical event has occurred via the OAMPDU flags field to its peer OAM
                                         entity.  If the system does not support dying gasp capability,
                                         reading the object should always result in 'disabled(2)'.
                                         
                                         By default, this object should have the value enabled(1) for
                                         Ethernet like interfaces that support OAM.  If the OAM layer
                                         does not support event notifications (as indicated via the
                                         OamFunctionsSupported attribute), this value is ignored."
                        ::= { cienaCesOamEventConfigEntry 12 }
                                                               
                                                               
    --
    -- Notifications
    --  

    cienaCesOamLinkEventTrap  NOTIFICATION-TYPE
        OBJECTS     {                                                        
                         cienaGlobalSeverity,
                         cienaGlobalMacAddress,
                         cienaCesOamEventNotifChassisIndex,
                         cienaCesOamEventNotifShelfIndex, 
                         cienaCesOamEventNotifSlotIndex, 
                         cienaCesOamEventNotifPortNumber,
                         cienaCesOamEventLogType,
                         cienaCesOamEventLogLocation,
                         cienaCesOamEventNotifChannelNumber
                    }
         STATUS     current
         DESCRIPTION
                     "A cienaCesOamLinkEventTrap notification is sent whenever a local or remote link event is detected
                      and recorded in the cienaCesOamEventLogTable.
                      To enable the device to send this trap, cienaCesOamLinkEventTrapState needs to be set to enabled. 
                      The cienaCesOamLinkEventTrapState is enabled by default. Variable bindings include: 
                      cienaGlobalSeverity, cienaGlobalMacAddress, cienaCesOamEventNotifChassisIndex, 
                      cienaCesOamEventNotifShelfIndex, cienaCesOamEventNotifSlotIndex, cienaCesOamEventNotifPortNumber,
                      cienaCesOamEventLogType, cienaCesOamEventLogLocation, and cienaCesOamEventNotifChannelNumber."
            ::= { cienaCesOamNotifMIBNotification 1 }

        END

--
-- CIENA-CES-OAM-MIB.my
--