--  SIAE MICROELETTRONICA s.p.a.
--
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-PTP-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
        FROM SNMPv2-SMI
             DisplayString, RowStatus, TruthValue, TEXTUAL-CONVENTION
        FROM SNMPv2-TC
             InterfaceIndex
        FROM IF-MIB
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;

    ptp MODULE-IDENTITY
        LAST-UPDATED "201605050000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: help@siaemic.com
            "
        DESCRIPTION
            "SIAE's Precision Time Protocol MIB.
            For details see:
            [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
                Synchronization Protocol for Networked Measurement and
                Control Systems, 2008.
            [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
                telecom profile for phase/time synchronization with full timing
                support from the network, draft 4 Apr 2014 . "
      ::= { siaeMib 100 }

--
-- Textual Conventions for PTP
--

    ClockDomainType ::= TEXTUAL-CONVENTION
        DISPLAY-HINT    "d"
        STATUS          current
        DESCRIPTION
            "The Domain is identified by an integer, the domainNumber, in
            the range of 0 to 255. An integer value that is used to assign
            each PTP device to a particular domain. The following values
            define the valid domains. [1] Section 7.1 Domains Table 2

                     Value       definition.
                     ---------   -------------------
                     0           Default domain
                     1           Alternate domain 1
                     2           Alternate domain 2
                     3           Alternate domain 3
                     4 - 23      User-defined domains
                     24 - 43     Telecom Profile domains
                     44 - 127    User-defined domains
                     128 - 255   Reserved"

        REFERENCE       "Section 7.1 Domains and Table 2 of [1]"
        SYNTAX          Unsigned32 (24..43)

    ClockProfileType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "Clock Profile used. A profile is the set of allowed Precision
            Time Protocol (PTP) features applicable to a device."

        REFERENCE       "Section 3.1.30 and 19.3 PTP profiles of
                         [IEEE 1588-2008]"
        SYNTAX          INTEGER  {
                            default(1),
                            telecom(2),
                            vendorspecific(3)
                        }

    ClockQualityAccuracyType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "The ClockQuality as specified in section 5.3.7, 7.6.2.5 and
            Table 6 of [1].

            The following values are not represented in the enumerated
            values.

                     0x01-0x1F Reserved
                     0x32-0x7F Reserved

            It is important to note that section 7.1.1 RFC2578 allows for
            gaps and enumerate values to start with zero when indicated by
            the protocol."

        REFERENCE       "Section 5.3.7, 7.6.2.5 and Table 6 of [1]"
        SYNTAX          INTEGER  {
                            reserved00(1), -- 0
                            nanoSecond25(32), -- 0x20
                            nanoSecond100(33), -- 0x21
                            nanoSecond250(34), -- 0x22
                            microSec1(35), -- 0x23
                            microSec2dot5(36), -- 0x24
                            microSec10(37), -- 0x25
                            microSec25(38), -- 0x26
                            microSec100(39), -- 0x27
                            microSec250(40), -- 0x28
                            milliSec1(41), -- 0x29
                            milliSec2dot5(42), -- 0x2A
                            milliSec10(43), -- 0x2B
                            milliSec25(44), -- 0x2C
                            milliSec100(45), -- 0x2D
                            milliSec250(46), -- 0x2E
                            second1(47), -- 0x2F
                            second10(48), -- 0x30
                            secondGreater10(49), -- 0x31
                            unknown(254), -- 0xFE
                            reserved255(255) -- 0xFF
                        }

    ClockQualityClassType ::= TEXTUAL-CONVENTION
        DISPLAY-HINT    "d"
        STATUS          current
        DESCRIPTION
            "The ClockQuality as specified in section 5.3.7, 7.6.2.4 and
            Table 5 of [1].

             Value    Description
             ------
            ----------------------------------------------------------
                   0  Reserved to enable compatibility with future
                      versions.
                 1-5  Reserved
                   6  Shall designate a clock that is synchronized
                      to a primary reference time source.  The
                      timescale distributed shall be PTP.  A
                      clockClass 6 clock shall not be a slave to
                      another clock in the domain.
                   7  Shall designate a clock that has previously
                      been designated as clockClass 6 but that has
                      lost the ability to synchronize to a primary
                      reference time source and is in holdover mode
                      and within holdover specifications. The
                      timescale distributed shall be PTP.  A
                      clockClass 7 clock shall not be a slave to
                      another clock in the domain.
                   8  Reserved.
                9-10  Reserved to enable compatibility with future
                      versions.
               11-12  Reserved.
                  13  Shall designate a clock that is synchronized
                      to an application-specific source of time.
                      The timescale distributed shall be ARB.  A
                      clockClass 13 clock shall not be a slave to
                      another clock in the domain.
                  14  Shall designate a clock that has previously
                      been designated as clockClass 13 but that
                      has lost the ability to synchronize to an
                      application-specific source of time and is
                      in holdover mode and within holdover
                      specifications. The timescale distributed
                      shall be ARB.  A clockClass 14 clock shall
                      not be a slave to another clock in the domain.
               15-51  Reserved.
                  52  Degradation alternative A for a clock of
                      clockClass 7 that is not within holdover
                      specification.  A clock of clockClass 52
                      shall not be a slave to another clock in
                      the domain.
               53-57  Reserved.
                  58  Degradation alternative A for a clock of
                      clockClass 14 that is not within holdover
                      specification. A clock of clockClass 58 shall
                      not be a slave to another clock in the domain.
               59-67  Reserved.
              68-122  For use by alternate PTP profiles.
             123-127  Reserved.
             128-132  Reserved.
             133-170  For use by alternate PTP profiles.
             171-186  Reserved.

                 187  Degradation alternative B for a clock of
                      clockClass 7 that is not within holdover
                      specification. A clock of clockClass 187 may
                      be a slave to another clock in the domain.
             188-192 Reserved.
                 193 Degradation alternative B for a clock of
                     clockClass 14 that is not within holdover
                     specification. A clock of clockClass 193 may
                     be a slave to another clock in the domain.
             194-215 Reserved.
             216-232 For use by alternate PTP profiles.
             233-247 Reserved.
                 248 Default. This clockClass shall be used if
                     none of the other clockClass definitions apply.
             249-250 Reserved.
                 251 Reserved for version 1 compatibility; see Clause 18.
             252-254 Reserved.
                 255 Shall be the clockClass of a slave-only clock; see
            9.2.2.

            The ClockQuality as specified in section 6.4 and
            Table 2 of [2].

             Value    Description
             ------
            ----------------------------------------------------------
                   6 T-GM connected to a PRTC in locked mode
                     (e.g. PRTC traceable to GNSS)
                 140 T-GM in holdover, out of holdover specification,
                     traceable to Category 1 frequency source
                 150 T-GM in holdover, out of holdover specification,
                     traceable to Category 2 frequency source
                 160 T-GM in holdover, out of holdover specification,
                     traceable to Category 3 frequency source
                 165 T-BC in holdover, out of holdover specification,
                     using unspecified frequency source
                 255 Slave only OC (does not send Announce messages)

            "

        REFERENCE       "section 5.3.7, 7.6.2.4 and Table 5 of [1].
                         section 6.4 and Table 2 of [2]"
        SYNTAX       INTEGER (0..255)

    ClockStateType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "The clock state returned by PTP engine.

            Clock State             Value   Description
            --------------------------------------------------------------
            Freerun state           1       The PTP clock has never been synchronized
                                            to a time source and is not in the process
                                            of synchronizing to a time source.
                                            As it relates to the PTP port state defined
                                            in [IEEE 1588], a clock is in Free-Run state
                                            if there are no PTP ports in: MASTER,
                                            PRE-MASTER, PASSIVE, UNCALIBRATED,
                                            or SLAVE states.

            Acquiring state         2       The PTP clock is in process of synchronizing
                                            to a time source. The duration and functionality
                                            of this state is implementation specific. This
                                            state is not required in an implementation.
                                            As it relates to the PTP port state defined in
                                            [IEEE 1588], a clock is in Acquiring state if
                                            there is a PTP port in UNCALIBRATED state.

            Locked state            3       The PTP clock is synchronized to a time source
                                            and is within some internal acceptable accuracy.
                                            As it relates to the PTP port state defined in
                                            [IEEE 1588], a clock is in Locked state if there
                                            is a PTP port in SLAVE state.

            HoldoverInSpec state    4       The PTP clock is no longer synchronized to a
                                            time source and is using information obtained
                                            while it was previously synchronized or other
                                            information sources were still available, to
                                            maintain performance within desired specification.
                                            The node may be relying solely on its own
                                            facilities for holdover or may use something
                                            like a frequency input from the network to
                                            achieve a holdover of time and/or phase.
                                            As it relates to the PTP port state defined in
                                            [IEEE 1588], a clock is in HoldoverInSpec
                                            state if there are no PTP ports in: INITIALIZING,
                                            LISTENING, UNCALIBRATED or SLAVE states, and
                                            performance is within desired specification.

            HoldoverOutOfSpec state 5       The PTP clock is no longer synchronized to a time
                                            source and, while it may be using information
                                            obtained while it was previously synchronized or
                                            other information sources were still available,
                                            it is unable to maintain performance within
                                            desired specification.
                                            As it relates to the PTP port state defined in
                                            [IEEE 1588], a clock is in HoldoverOutOfSpec
                                            state if there are no PTP ports in: INITIALIZING,
                                            LISTENING, UNCALIBRATED or SLAVE states, and
                                            performance is not within desired specification."
        SYNTAX          INTEGER  {
                            freerun(1),
                            acquiring(2),
                            locked(3),
                            holdoverInSpec(4),
                            holdoverOutOfSpec(5)
                        }

    ClockTimeSourceType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "The ClockQuality as specified in section 5.3.7, 7.6.2.6 and
            Table 7 of [1].

            The following values are not represented in the enumerated
            values.

            0xF0-0xFE  For use by alternate PTP profiles
            0xFF       Reserved

            It is important to note that section 7.1.1 RFC2578 allows for
            gaps and enumerate values to start with zero when indicated by
            the protocol."

        REFERENCE       "section 5.3.7, 7.6.2.6 and Table 7 of [1]."
        SYNTAX          INTEGER  {
                            atomicClock(16), -- 0x10
                            gps(32), -- 0x20
                            terrestrialRadio(48), -- 0x22
                            ptp(64), -- 0x40
                            ntp(80), -- 0x50
                            handSet(96), -- 0x60
                            other(144), -- 0x90
                            internalOscillator(160), -- 0xA0
                            reserved(255) --0xFF
                        }

    ClockInstanceType ::= TEXTUAL-CONVENTION
        DISPLAY-HINT    "d"
        STATUS          current
        DESCRIPTION
            "The instance of the Clock of a given clock type in a given
            domain."
        SYNTAX          Unsigned32 (0..255)
		
		
    ClockPPSInstanceType ::= TEXTUAL-CONVENTION
        DISPLAY-HINT    "d"
        STATUS          current
        DESCRIPTION
            "The instance of the PPS (and ToD) socket."
        SYNTAX          Unsigned32 (0..255)


    ClockPortNumber ::= TEXTUAL-CONVENTION
        DISPLAY-HINT    "d"
        STATUS          current
        DESCRIPTION
            "An index identifying a specific Precision Time Protocol (PTP)
            port on a PTP node."
        REFERENCE       "Section 7.5.2.3 Port Number and 5.3.5 of [1]"
        SYNTAX          Unsigned32 (0..65535)

		
    ClockPortState ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "This is the value of the current state of the protocol engine
            associated with this port.
            Port state      Value     Description
            -----------------------------------------------------------
            initializing      1       In this state a port initializes
                                      its data sets, hardware, and
                                      communication facilities.
            faulty            2       The fault state of the protocol.
            disabled          3       The port shall not place any
                                      messages on its communication path.
            listening         4       The port is waiting for the
                                      announceReceiptTimeout to expire or
                                      to receive an Announce message from
                                      a master.
            preMaster         5       The port shall behave in all respects
                                      as though it were in the MASTER state
                                      except that it shall not place any
                                      messages on its communication path
                                      except for Pdelay_Req, Pdelay_Resp,
                                      Pdelay_Resp_Follow_Up, signaling, or
                                      management messages.
            master            6       The port is behaving as a master
                                      port.
            passive           7       The port shall not place any
                                      messages on its communication path
                                      except for Pdelay_Req, Pdelay_Resp,
                                      Pdelay_Resp_Follow_Up, or signaling
                                      messages, or management messages
                                      that are a required response to
                                      another management message
            uncalibrated      8       The local port is preparing to
                                      synchronize to the master port.
            slave             9       The port is synchronizing to the
                                      selected master port."

        REFERENCE       "Section 8.2.5.3.1 portState and 9.2.5 of [1]"
        SYNTAX          INTEGER  {
                            initializing(1),
                            faulty(2),
                            disabled(3),
                            listening(4),
                            preMaster(5),
                            master(6),
                            passive(7),
                            uncalibrated(8),
                            slave(9)
                        }

    ClockMechanismType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "The clock type based on whether End to End or peer to peer
            mechanisms are used. The mechanism used to calculate the Mean
            Path Delay as indicated in Table 9 of IEEE 1588-2008.

            Delay mechanism       Value(hex) Specification
            E2E                    01        The port is configured to use
                                             the delay request-response
                                             mechanism.

            P2P                    02        The port is configured to use
                                             the peer delay mechanism.

            DISABLED               FE        The port does not implement
                                             the delay mechanism."

        REFERENCE       "Sections 8.2.5.4.4, 6.6.4 and 7.4.2 of [1]."
        SYNTAX          INTEGER  {
                            e2e(1)
                            -- p2p(2),
                            -- disabled(254)
                        }

    ClockTimeInterval ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "This textual convention corresponds to the TimeInterval
            structure indicated in section 5.3.2 of [1]. It will be
            presented in the form of a character array.

            The TimeInterval type represents time intervals.

                 struct TimeInterval
                 {
                      Integer64 scaledNanoseconds;
                 };

            The scaledNanoseconds member is the time interval expressed in
            units of nanoseconds and multiplied by 2**16.

            Positive or negative time intervals outside the maximum range
            of this data type shall be encoded as the largest positive and
            negative values of the data type, respectively.

            For example, 2.5 ns is expressed as 0000 0000 0002 8000 in
            Base16."

        REFERENCE
            "Section 5.3.2 and setion 7.7.2.1 Timer interval
            specification of [1]"
        SYNTAX          OCTET STRING (SIZE (1..255))

    ClockType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "The clock types as defined in the MIB module description."

        REFERENCE       "section 6.5.1 of [1]."
        SYNTAX          INTEGER  {
                            --ordinaryClock(1),
                            boundaryClock(2)
                            --transparentClock(3),
                            --boundaryNode(4)
                        }

   PtpClockToDFormatType ::= TEXTUAL-CONVENTION
        STATUS          current
        DESCRIPTION
            "This is the format used for ToD signal in input or in output direcdtion.

            -----------------------------------------------------------			
            Format              Value  Description
            -----------------------------------------------------------
            telecomTimeEvent      1    
            telecomTimeAnnounce   2    
            telecomGNSSstatus     3    
			NMEAzda               4    ASCII format (eg: $GPZDA,003157.00,01,01,1970,00,00*69)
			ISO8601               5    ASCII format (eg: 1970-01-01T00:32:47Z)
			NTP                   6    ASCII format (eg: 70 001 00:30:51.000  S)
			Ublox                 7    Not ASCII
			ChinaMobile           8    Not ASCII
			ChinaTelecom          9    Not ASCII (standard ITU G.8271 is derived from this)
			BCM                  10    Not ASCII
			BCMTS                11    Not ASCII
            -----------------------------------------------------------"
        SYNTAX          INTEGER  {
                            telecomTimeEvent(1),
                            telecomTimeAnnounce(2),
                            telecomGNSSstatus(3),
                            nmeazda(4),
                            iso8601(5),
                            ntp(6),
                            ublox(7),
                            chinaMobile(8),
                            chinaTelecom(9),
							bcm(10),
							bcmts(11)
                        }

--------------------------------------------------------------------------------
--  PTP GROUP
--------------------------------------------------------------------------------
--
-- This group is used for Precision Time Protocol version 2 configuration and alarm reporting
--
-- For details see:
--    [1] IEEE Std 1588(TM)-2008, Standard for a Precision Clock
--        Synchronization Protocol for Networked Measurement and
--        Control Systems, 2008.
--    [2] Recommendation ITU-T G.8275.1/Y1369.1, Precision time protocol
--        telecom profile for phase/time synchronization with full timing
--        support from the network, draft 4 Apr 2014 .
--
--------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------

    ptpMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
        DEFVAL {1}
    ::= { ptp 1 }


    ptpProfileDataSet        OBJECT IDENTIFIER ::= { ptp  2 }
    ptpSpecificDataSet       OBJECT IDENTIFIER ::= { ptp  3 }
    ptpDefaultDataSet        OBJECT IDENTIFIER ::= { ptp  4 }
    ptpCurrentDataSet        OBJECT IDENTIFIER ::= { ptp  5 }
    ptpParentDataSet         OBJECT IDENTIFIER ::= { ptp  6 }
    ptpTimePropertiesDataSet OBJECT IDENTIFIER ::= { ptp  7 }
    ptpPortDataSet           OBJECT IDENTIFIER ::= { ptp  8 }
	ptpClockPPSDataSet       OBJECT IDENTIFIER ::= { ptp  9 }
	ptpRadioAsymmetryDataSet OBJECT IDENTIFIER ::= { ptp 10 }

-------  Begin of Ptp Profile data set.
--

    ptpSystemProfile OBJECT-TYPE
        SYNTAX          ClockProfileType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object specifies the PTP Profile implemented on the
            system."
        REFERENCE       "Section 19.3 PTP profiles of [1]"
        ::= { ptpProfileDataSet 1 }

     ptpProfileName   OBJECT-TYPE
        SYNTAX          DisplayString (SIZE(0..128))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object describes the PTP Profile implemented on the system."
        REFERENCE       "Section 19.3 PTP profiles of [1]"
--        DEFVAL { "ITU-T PTP profile for phase/time distribution with full timing support from the network" }
        ::= { ptpProfileDataSet 2 }

     ptpProfilePrimaryVersion OBJECT-TYPE
        SYNTAX          Integer32(0..65535)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The version of the profile consist of two fields: a primaryVersion
            and a revisionNumber. The profileVersion shall be printed as
                primaryVersion.revisionNumber
            "
        REFERENCE       "Section 19.3 PTP profiles of [1]"
        DEFVAL { 1 }
        ::= { ptpProfileDataSet 3 }

     ptpProfileRevisionNumber OBJECT-TYPE
        SYNTAX          Integer32(0..255)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "The version of the profile consist of two fields: a primaryVersion
            and a revisionNumber. The profileVersion shall be printed as
                primaryVersion.revisionNumber
            "
        REFERENCE       "Section 19.3 PTP profiles of [1]"
        DEFVAL { 0 }
        ::= { ptpProfileDataSet 4 }

     ptpProfileIdentifier OBJECT-TYPE
        SYNTAX          OCTET STRING  (SIZE(6))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object show the PTP Profile version on the system."
        REFERENCE       "Section 19.3 PTP profiles of [1]"
        DEFVAL {'0019A7010100'h}
        ::= { ptpProfileDataSet 5 }

--
-------  End of Ptp Profile data set.




-------  Begin of Ptp Default data set.
--       Characterizes the PTP clock of the system.
--

    ptpClockDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpClockDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of information about the PTP clock Default Datasets for
         all domains."
        ::= { ptpDefaultDataSet 1 }

    ptpClockDataSetEntry   OBJECT-TYPE
        SYNTAX      PtpClockDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
         "Contains the information of the clock on a particular doamin. This
          table will be initialised with default values if the clock is
          operating as a boundary or ordinary clock in the domain."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex }
        ::= { ptpClockDataSetTable 1 }

    PtpClockDataSetEntry ::= SEQUENCE {
             ptpClockDomainIndex              ClockDomainType,
             ptpClockTypeIndex                ClockType,
             ptpClockInstanceIndex            ClockInstanceType,
             ptpClockIdentity                 OCTET STRING,
             ptpClockTwoStepFlag              TruthValue,
             ptpClockNumberPorts              Integer32,
             ptpClockClass                    ClockQualityClassType,
             ptpClockAccuracy                 ClockQualityAccuracyType,
             ptpClockOffsetScaledLogVariance  Integer32,
             ptpClockPriority1                Integer32,
             ptpClockPriority2                Integer32,
             ptpClockSlaveOnly                TruthValue,
             ptpClockLocalPriority            INTEGER,
             ptpClockRowStatus                RowStatus
    }

    ptpClockDomainIndex OBJECT-TYPE
        SYNTAX          ClockDomainType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object specifies the domain number used to create logical
        group of PTP devices. The Clock Domain is a logical group of
        clocks and devices that synchronize with each other using the
        PTP protocol."
        ::= { ptpClockDataSetEntry 1 }

    ptpClockTypeIndex OBJECT-TYPE
        SYNTAX          ClockType
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object specifies the clock type as defined in the
        Textual convention description."
        ::= { ptpClockDataSetEntry 2 }

    ptpClockInstanceIndex OBJECT-TYPE
        SYNTAX          ClockInstanceType (0..255)
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object specifies the instance of the Clock for this clock
        type for the given domain."
        ::= { ptpClockDataSetEntry 3 }

    ptpClockIdentity OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE (8))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the unique identity of the local clock or management node.
         This should be the smptpDomainClockIdentity of the domain indicated
         by the ptpDomainNumber. Configuration of this value will take effect
         only when the PTP module is enabled."
        ::= {ptpClockDataSetEntry  4 }

    ptpClockTwoStepFlag OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This value is TRUE if the clock is two step clock, otherwise it is
        FALSE. If this value is configured as TRUE, then PTP will transmit the
        originTimeStamp only through follow-up messages."
        DEFVAL { false }
        ::= { ptpClockDataSetEntry 5 }

    ptpClockNumberPorts OBJECT-TYPE
        SYNTAX      Integer32 (1..128)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This indicates the number of PTP ports on the device. For an ordinary
         clock this value should be 1."
        DEFVAL { 6 }
        ::= { ptpClockDataSetEntry 6 }

    ptpClockClass OBJECT-TYPE
        SYNTAX      ClockQualityClassType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object specifies the default dataset Quality Class."
        DEFVAL { 248 }
        ::= { ptpClockDataSetEntry 7 }

    ptpClockAccuracy OBJECT-TYPE
        SYNTAX      ClockQualityAccuracyType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object specifies the default dataset Quality Accurarcy."
        DEFVAL { unknown }
        ::= { ptpClockDataSetEntry 8 }

    ptpClockOffsetScaledLogVariance OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This value is an estimate of the variations of the local clock
         from a linear timescale when it is not synchronized to another
         clock using the protocol. The initialization value depends on the
         inherent characteristics of the clock during initialization. This
         value is used by the BMC algorithm to select the best master clock"
        DEFVAL { 0 }
        ::= { ptpClockDataSetEntry 9 }

    ptpClockPriority1 OBJECT-TYPE
        SYNTAX      Integer32 (128)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This value is used by BMC algorithm to select the best master
         clock. Lower values take precedence."
        DEFVAL { 128 }
        ::= { ptpClockDataSetEntry 10 }

    ptpClockPriority2 OBJECT-TYPE
        SYNTAX      Integer32 (1..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This value is used by BMC algorithm to select the best master clock.
        This is used as a tiebreaker when the BMC failes to order the clock
        using  ptpClockPriority1, ptpClockClass, ptpClockAccuracy and
        ptpClockOffsetScaledLogVariance.
        Lower values take precedence"
        DEFVAL { 128 }
        ::= { ptpClockDataSetEntry 11 }

    ptpClockSlaveOnly OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "Configuring this value as true will make the clock to behave as slave
        clock.
        A boundary clock can not be a slave only clock."
        DEFVAL { false }
        ::= { ptpClockDataSetEntry 12 }

    ptpClockLocalPriority OBJECT-TYPE
        SYNTAX      INTEGER (1..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used in the alternate BMCA as a tie-breaker in the
         dataset comparison algorithm, in the event that all other previous
         attributes of the datasets being compared are equal."
        REFERENCE       "Section 6.3.1 and 6.3.2 of [2]"
        DEFVAL { 128 }
        ::= { ptpClockDataSetEntry 13 }

    ptpClockRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "RowStatus for creating the entries into this table.
         This object support only destroy and createAndGo values."
        ::= { ptpClockDataSetEntry  14 }


--
-------  End of Ptp Default data set.


-------  Begin of Ptp Specific data set
--       Contains global configuration/information
--       of a particular PTP clock.
--

    ptpSpecificDataSetTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpSpecificDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of vendor specific information about the PTP clock
         for all domains."
        ::= { ptpSpecificDataSet 1 }

    ptpSpecificDataSetEntry OBJECT-TYPE
        SYNTAX      PtpSpecificDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Contains vendor specific information for a particular PTP clock.
         Where not otherwise specified, every object of this entry can 
         be modified with the conceptual row active."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex
              }
        ::= { ptpSpecificDataSetTable 1 }

    PtpSpecificDataSetEntry ::= SEQUENCE {
            ptpAdminStatus      INTEGER,
            ptpStaticPortRole   TruthValue,
            ptpClockState       ClockStateType,
            ptpCompliance       INTEGER
    }

    ptpAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                               down   (1),
                               up     (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object states if PTP is enabled or disabled for this PTP Clock
         in order to switch on/off the PTP protocol."
        DEFVAL { down }
        ::= { ptpSpecificDataSetEntry 1 }

    ptpStaticPortRole   OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object states that in the PTP Clock the A-BMCA is disabled and
         it is working in Static PTP Port Role mode."
        DEFVAL { false }
        ::= { ptpSpecificDataSetEntry 2 }

    ptpClockState OBJECT-TYPE
        SYNTAX      ClockStateType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object shows the current state of the PTP Clock State Machine"
        ::= { ptpSpecificDataSetEntry 3 }

    ptpCompliance OBJECT-TYPE
        SYNTAX      INTEGER {
                              strictCompatibility (1),
                              looseCompatibility  (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object states if the clock is strictly profile compliant. The
         meaning of looseCompatibility is application dependent."
        DEFVAL { looseCompatibility }
        ::= { ptpSpecificDataSetEntry 4 }

    --
    --  Ptp Specific alarms. Contains alarms of a particular PTP clock 
    -- .

    ptpSpecificAlarmTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpSpecificAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of vendor specific information about the PTP clock
         for all domains."
        ::= { ptpSpecificDataSet 2 }

    ptpSpecificAlarmEntry OBJECT-TYPE
        SYNTAX      PtpSpecificAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Contains vendor specific alarm information for a particular PTP clock."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex
              }
        ::= { ptpSpecificAlarmTable 1 }

    PtpSpecificAlarmEntry ::= SEQUENCE {
        ptpFreeRunningAlarm       AlarmStatus,
        ptpHoldoverInSpecAlarm    AlarmStatus,
        ptpHoldoverOutOfSpecAlarm AlarmStatus
    }

    ptpFreeRunningAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpClockState is set to freerun(1).
            "
        ::=  { ptpSpecificAlarmEntry  1 }

    ptpHoldoverInSpecAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpClockState is set to
             holdoverInSpec(4).
            "
        ::=  { ptpSpecificAlarmEntry  2 }

    ptpHoldoverOutOfSpecAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpClockState is set to 
             holdoverOutOfSpec(5).
            "
        ::=  { ptpSpecificAlarmEntry  3 }

    --
    --  Ptp specific alarm severities.
    --  

    ptpFreeRunningAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to 
             ptpFreeRunningAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { warningTrapEnable }
        ::= { ptpSpecificDataSet 3 }

    ptpHoldoverInSpecAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to 
             ptpHoldoverInSpecAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { warningTrapEnable }
        ::= { ptpSpecificDataSet 4 }

    ptpHoldoverOutOfSpecAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to 
             ptpHoldoverOutOfSpecAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { majorTrapEnable }
        ::= { ptpSpecificDataSet 5 }

--
-------  End of Ptp Specific data set.


-------  Begin of Ptp Current data set.
--       Synchronization information of the PTP clock.
--

    ptpCurrentDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpCurrentDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of information about the PTP clock Current Datasets for
         all domains."
    ::= { ptpCurrentDataSet 1 }

    ptpCurrentDataSetEntry   OBJECT-TYPE
        SYNTAX       PtpCurrentDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                " Contains synchronization information on a particular domain."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex }
        ::= { ptpCurrentDataSetTable 1 }

    PtpCurrentDataSetEntry ::= SEQUENCE {
             ptpCurrentStepsRemoved         Integer32,
             ptpCurrentOffsetFromMaster     ClockTimeInterval,
             ptpCurrentMeanPathDelay        ClockTimeInterval
    }

    ptpCurrentStepsRemoved OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object specifies the distance measured by the number of
         Boundary clocks between the local clock and the Foreign master
         as indicated in the stepsRemoved field of Announce messages.
         Slave clock will update this field once port is selected as slave."
        REFERENCE    "1588 Version 2.0 Section 8.2.2.2 stepsRemoved"
        ::= { ptpCurrentDataSetEntry 1 }

    ptpCurrentOffsetFromMaster OBJECT-TYPE
        SYNTAX      ClockTimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object specifies the current clock dataset ClockOffset
         value. The value of the computation of the offset in time
         between a slave and a master clock."
        REFERENCE   "1588 Version 2.0 Section 8.2.2.3 of [1]"
        ::= { ptpCurrentDataSetEntry 2 }

    ptpCurrentMeanPathDelay OBJECT-TYPE
        SYNTAX      ClockTimeInterval
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This object specifies the current clock dataset
         MeanPathDelay value.
         The mean path delay between a pair of ports as measure by the
         delay request-response mechanism."
        REFERENCE   "1588 Version 2.0 Section 8.2.2.4 mean path delay"
        ::= { ptpCurrentDataSetEntry 3 }

--
-------  End of Ptp Current data set.



-------  Begin of Ptp Parent data set.
--       Information about parent PTP clock.
--

    ptpParentDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpParentDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of information about the PTP clock Parent Datasets for
         all domains."
        ::= { ptpParentDataSet 1 }

    ptpParentDataSetEntry   OBJECT-TYPE
        SYNTAX       PtpParentDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains parent clock information on a particular domain. "
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex }
        ::= { ptpParentDataSetTable 1 }

    PtpParentDataSetEntry ::= SEQUENCE {
             ptpParentClockIdentity                   OCTET STRING,
             ptpParentPortNumber                      ClockPortNumber,
             ptpParentGMClockIdentity                 OCTET STRING,
             ptpParentGMClockClass                    ClockQualityClassType,
             ptpParentGMClockAccuracy                 ClockQualityAccuracyType,
             ptpParentGMClockOffsetScaledLogVariance  Integer32,
             ptpParentGMPriority1                     Integer32,
             ptpParentGMPriority2                     Integer32
    }

    ptpParentClockIdentity OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE (8))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the clock identity of the port on the master that issues
         sync messages used in synchronizing this clock. The initial value
         of this field is the value of ptpClockIdentity"
        REFERENCE   "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
        ::= { ptpParentDataSetEntry 1 }

    ptpParentPortNumber OBJECT-TYPE
        SYNTAX      ClockPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the port number identity of the port on the master that issues
         sync message used in synchronizing this clock. Combination of
         ptpParentClockIdentity and ptpParentPortNumber gives the port identity
         of the parent clock."
        REFERENCE   "section 8.2.3.2 parentDS.parentPortIdentity of [1]"
        ::= { ptpParentDataSetEntry 2 }

    ptpParentGMClockIdentity OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE (8))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the clock identity attribute of the grand master clock.
         The initial value is ptpClockIdentity."
        REFERENCE   "section 8.2.3.6 parentDS.grandmasterIdentity of [1]"
        ::= { ptpParentDataSetEntry 3 }

    ptpParentGMClockClass OBJECT-TYPE
        SYNTAX      ClockQualityClassType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the clock class of the grandmaster. The
         initialization value of this variable is ptpClockClass."
        REFERENCE   "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
        ::= { ptpParentDataSetEntry 4 }

    ptpParentGMClockAccuracy OBJECT-TYPE
        SYNTAX      ClockQualityAccuracyType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the clock accuracy of the grandmaster. The
         initialization value of this variable is ptpClockAccuracy"
        REFERENCE   "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
        ::= { ptpParentDataSetEntry 5 }

    ptpParentGMClockOffsetScaledLogVariance OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the offset scaled log variance of the grandmaster. The
         initialization value of this variable is
         ptpClockOffsetScaledLogVariance"
        REFERENCE "section 8.2.3.7 parentDS.grandmasterClockQuality of [1]"
        ::= { ptpParentDataSetEntry 6 }

    ptpParentGMPriority1 OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the priority1 of the grandmaster clock. The
         initialization value of this variable is ptpClockPriority1"
        REFERENCE "section 8.2.3.8 parentDS.grandmasterPriority1 of [1]"
        ::= { ptpParentDataSetEntry 7 }

    ptpParentGMPriority2 OBJECT-TYPE
        SYNTAX      Integer32 (0..255)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the priority2 of the grandmaster clock. The
             initialization value of this variable is ptpClockPriority2"
        REFERENCE "section 8.2.3.9 parentDS.grandmasterPriority2 of [1]"
        ::= { ptpParentDataSetEntry 8 }

--
-------  End of Ptp Parent data set.



-------  Begin of Ptp Time properties data set.
--       Global time properties of the clock.
--

    ptpTimeDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpTimeDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of information about the PTP clock Timeproperties
        Datasets for all domains."
        ::= { ptpTimePropertiesDataSet 1 }

    ptpTimeDataSetEntry   OBJECT-TYPE
        SYNTAX      PtpTimeDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains parent Time properties information of the
                 clock on a particular domain."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex }
        ::= { ptpTimeDataSetTable 1 }

    PtpTimeDataSetEntry ::= SEQUENCE {
             ptpTimeCurrentUTCOffset       Integer32,
             ptpTimeCurrentUTCOffsetValid  TruthValue,
             ptpTimeLeap59                 TruthValue,
             ptpTimeLeap61                 TruthValue,
             ptpTimeTimeTraceable          TruthValue,
             ptpTimeFrequencyTraceable     TruthValue,
             ptpTimescale                  TruthValue,
             ptpTimeTimeSource             ClockTimeSourceType
    }

    ptpTimeCurrentUTCOffset OBJECT-TYPE
        SYNTAX      Integer32 (0..65535)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "If systems epoch is the PTP epoch then this value indicates the offset
        in seconds between TAI and UTC."
        REFERENCE "section 8.2.4.2 timePropertiesDS.currentUtcOffset of [1]"
        ::= { ptpTimeDataSetEntry 1 }

    ptpTimeCurrentUTCOffsetValid OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "Value of this variable is TRUE if the ptpTimeCurrentUTCOffset is
        known to be correct."
        REFERENCE "section 8.2.4.3 timePropertiesDS.currentUtcOffsetValid of [1]"
        ::= { ptpTimeDataSetEntry 2 }

    ptpTimeLeap59 OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "If the systems epoch is PTP epoch then TRUE value of this variable
        indicates that the last minute of the current UTC day contains 59
        seconds."
        REFERENCE "section 8.2.4.4 timePropertiesDS.leap59 of [1]"
        ::= { ptpTimeDataSetEntry 3 }

    ptpTimeLeap61 OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "If the systems epoch is PTP epoch then TRUE value of this variable
        indicates that the last minute of the current UTC day contains 61
        seconds."
        REFERENCE "section 8.2.4.5 timePropertiesDS.leap61 of [1]"
        ::= { ptpTimeDataSetEntry 4 }

    ptpTimeTimeTraceable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This variable is TRUE if the timescale and value of
        ptpTimeCurrentUTCOffset are traceable to a primary reference
        otherwise, the value shall be FALSE."
        REFERENCE "section  8.2.4.6 timePropertiesDS.timeTraceable of [1]"
        ::= { ptpTimeDataSetEntry 5 }

    ptpTimeFrequencyTraceable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This variable is TRUE if the frequecy determining the timescale is
        traceable to a primary reference otherwise, the value shall be FALSE."
        REFERENCE "section 8.2.4.7 timePropertiesDS.frequencyTraceable of [1]"
        ::= { ptpTimeDataSetEntry 6 }

    ptpTimescale OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This variable is TRUE if the clock timescale of the grandmaster clock
        is PTP otherwise, the value shall be FALSE."
        REFERENCE "section 8.2.4.8 timePropertiesDS.ptpTimescale of [1]"
        ::= { ptpTimeDataSetEntry 7 }

    ptpTimeTimeSource OBJECT-TYPE
        SYNTAX   ClockTimeSourceType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the source of time used by the grandmaster clock. If the time
        source is known at the time of initialization then the value will be set
        to that otherwise the initial value is INTERNAL_OSCILLATOR(160)."
        REFERENCE "section 8.2.4.9 timePropertiesDS.timeSource of [1]"
        DEFVAL { internalOscillator }
        ::= { ptpTimeDataSetEntry 8 }

--
-------  End of Ptp Time properties data set.

-------  Begin of Ptp PPS and ToD properties data set.
--

    ptpClockPPSDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpClockPPSDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "Table of information about the PTP clock PPS and ToD properties."
        ::= { ptpClockPPSDataSet 1 }

    ptpClockPPSDataSetEntry   OBJECT-TYPE
        SYNTAX      PtpClockPPSDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains PPS and ToD properties information of the
                 specific domain and clock on a specific PPS socket."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex,
				ptpClockPPSInstanceIndex }
        ::= { ptpClockPPSDataSetTable 1 }

	PtpClockPPSDataSetEntry ::= SEQUENCE {
			ptpClockPPSInstanceIndex     ClockPPSInstanceType,
			ptpClockPPSInstanceCapability  Unsigned32,
			ptpClockPPSDirection           INTEGER,

			ptpClockPPSLabel               DisplayString,
			ptpClockPPSAdminStatus         INTEGER,
			ptpClockPPSOffsetEnabled       TruthValue,
			ptpClockPPSOffsetValue         Integer32,

			ptpClockToDLabel               DisplayString,
            ptpClockToDAdminStatus         INTEGER,
			ptpClockToDDelay               Unsigned32,
			ptpClockToDBaudrate            Unsigned32,
			ptpClockToDFormat              PtpClockToDFormatType
	}

	
	ptpClockPPSInstanceIndex OBJECT-TYPE
        SYNTAX          ClockPPSInstanceType
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
        "This object specifies the id of PPS interface socket.
         It represents the id of ToD interface socket too."
		DEFVAL { 0 }
        ::= { ptpClockPPSDataSetEntry 1 }


	ptpClockPPSInstanceCapability OBJECT-TYPE
        SYNTAX          Unsigned32
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object is a bitmap and each bit represents 
         a specific capability of the PPS or ToD interface.
         Bit 0 : 1 = the interface can be used either in input or in output
                     and the user can select the direction using ptpClockPPSDirection object; 
                 0 = the interface can have one direction specified by the system, 
                     in this case the ptpClockPPSDirection object is read only.
         Bit 1 : 1 = the ToD interface allows more baudrate;
                 0 = the ToD interface allows one only baudrate, fixed by system.   "
		DEFVAL { 0 }
        ::= { ptpClockPPSDataSetEntry 2 }


	ptpClockPPSDirection OBJECT-TYPE
        SYNTAX          INTEGER {
                                  input  (1),
                                  output (2)
                                 }
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
        "This object specifies the direction (input or output) 
         of PPS signal and ToD data"
		DEFVAL { 2 }
        ::= { ptpClockPPSDataSetEntry 3 }


	ptpClockPPSLabel OBJECT-TYPE
        SYNTAX      DisplayString (SIZE(0..16))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object specifies the label as appears near the PPS signal socket"
		DEFVAL { "PPS" }
        ::= { ptpClockPPSDataSetEntry 4 }


    ptpClockPPSAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                              down (1),
                              up   (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object is the administrive status of PPS interface and
         specifies whether the node is enabled for PTP input/output 
         clocking using the PPS interface."
        DEFVAL { down }
        ::= { ptpClockPPSDataSetEntry 5 }


	ptpClockPPSOffsetEnabled OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object specifies whether an offset is configured 
		in order to compensate for a known phase error 
		such as network asymmetry."
        ::= { ptpClockPPSDataSetEntry 6 }


    ptpClockPPSOffsetValue OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object specifies the fixed offset signed value in nanoseconds 
		configured to be added for the PPS output or input."
        ::= { ptpClockPPSDataSetEntry 7 }


	ptpClockToDLabel OBJECT-TYPE
        SYNTAX      DisplayString (SIZE(0..16))
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
        "This object specifies the label as appears near the ToD socket"
		DEFVAL { "ToD" }
        ::= { ptpClockPPSDataSetEntry 8 }


	ptpClockToDAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER{
                              down (1),
                              up   (2)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object is the administrive status of PPS interface and 
         specifies whether the ToD interface is enabled." 
        DEFVAL { down }
        ::= { ptpClockPPSDataSetEntry 9 }


    ptpClockToDDelay OBJECT-TYPE
        SYNTAX      Unsigned32 (0..999999)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
		"This object specifies microseconds of delay between PPS edge 
		and ToD data emitted, used only in output direction."
		DEFVAL { 0 }
		::= { ptpClockPPSDataSetEntry 10 }


    ptpClockToDBaudrate OBJECT-TYPE
        SYNTAX      Unsigned32 (300|600|1200|1800|2400|4800|9600|19200|38400|57600|115200|230400)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
		"This object specifies the Baudrate of ToD signal in input or output direction."
		DEFVAL { 9600 }
		::= { ptpClockPPSDataSetEntry 11 }


    ptpClockToDFormat OBJECT-TYPE
        SYNTAX      PtpClockToDFormatType
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
		"This object specifies the format of ToD signal in input or output direction."
		DEFVAL { telecomTimeEvent }
		::= { ptpClockPPSDataSetEntry 12 }

--
-------  End of Ptp PPS and ToD properties data set.


-------  Begin of Ptp Port data set.
--       Configuration information of a particular PTP port.
--

    ptpPortDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpPortDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Table Contains PTP configuration information
                 for a particular port of boundary or an ordinary clock"
        ::= { ptpPortDataSet 1 }

    ptpPortDataSetEntry   OBJECT-TYPE
        SYNTAX      PtpPortDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains PTP configuration information for a particular port.
                 Valid ptpPortIfIndex need to be given to make this entry active.
                 Where not otherwise specified, every object of this entry 
                 can be modified with the conceptual row active."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex,
                ptpPortIndex
              }
        ::= { ptpPortDataSetTable 1 }

    PtpPortDataSetEntry ::= SEQUENCE {
            ptpPortIndex                   ClockPortNumber,
            ptpPortClockIdentity           OCTET STRING,
            ptpPortIfIndex                 InterfaceIndex,
            ptpPortStaticRole              INTEGER,
            ptpPortAdminStatus             INTEGER,
            ptpPortState                   ClockPortState,
            ptpPortMinDelayReqInterval     Integer32,
            ptpPortLogAnnounceInterval     Integer32,
            ptpPortAnnounceReceiptTimeout  Integer32,
            ptpPortSyncInterval            Integer32,
            ptpPortDelayMechanism          ClockMechanismType,
            ptpPortVersionNumber           Integer32,
            ptpPortNotSlave                TruthValue,
            ptpPortLocalPriority           Integer32,
            ptpPortDestMacAddress          INTEGER,
            ptpPortTxAsymmetryCompensation Integer32,
            ptpPortRxAsymmetryCompensation Integer32,
            ptpPortRowStatus               RowStatus
    }

    ptpPortIndex  OBJECT-TYPE
        SYNTAX      ClockPortNumber
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "The index value used to identify the port component on the device.
        The value of this object is used as a port index to the
        ptpPortConfigDataSetTable."
        ::= { ptpPortDataSetEntry 1 }

    ptpPortClockIdentity   OBJECT-TYPE
        SYNTAX      OCTET STRING (SIZE (8))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This is the clock Identity of the port"
        REFERENCE   "section 8.2.5.2.1 portDS.portIdentity of [1]"
        ::= { ptpPortDataSetEntry 2 }

    ptpPortIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This is the index in ifTable of this port.
         This object can't be modified."
        ::= { ptpPortDataSetEntry 3 }

    ptpPortStaticRole  OBJECT-TYPE
        SYNTAX      INTEGER {
                              master  (6),
                              passive (7),
                              slave   (9)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "Role of this port. This object forces the role of the port if
         ptpStaticPortRole is true."
        DEFVAL { master }
        ::= { ptpPortDataSetEntry 4}

    ptpPortAdminStatus  OBJECT-TYPE
        SYNTAX      INTEGER {
                              down    (1),
                              up      (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "Administrive status of the port. The value down turns off the PTP
         protocol on the ethernet port."
        DEFVAL { down }
        ::= { ptpPortDataSetEntry 5 }

    ptpPortState OBJECT-TYPE
        SYNTAX      ClockPortState
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        "This denotes the PTP State of the PTP port as computed by the PTP State
        event machine.

        initializing:
        While a port is in the INITIALIZING state, the port initializes its data
        sets, hardware, and communication facilities. No port of the clock shall
        place any PTP messages on its communication path. If one port of a
        boundary clock is in the INITIALIZING state, then all ports shall be in
        the INITIALIZING state.

        faulty:
        The fault state of the protocol. A port in this state shall not place any
        PTP messages except for management messages that are a required response
        to another management message on its communication path.

        disabled:
        The port shall not place any messages on its communication path. In a
        boundary clock, no activity at the port shall be allowed to affect the
        activity at any other port of the boundary clock. A port in this state
        shall discard all PTP received messages except for management messages.

        listening:
        The port is waiting for the announceReceiptTimeout to expire or to
        receive an Announce message from a master. The purpose of this state is
        to allow orderly addition of clocks to a domain. A port in this state
        shall not place any PTP messages on its communication path except for
        Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages,
        or management messages that are a required response to another
        management message.

        premaster:
        The port shall behave in all respects as though it were in the MASTER
        state except that it shall not place any messages on its communication
        path except for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, signaling
        or management messages.

        master:
        The port is behaving as a master port. It will periodically send announce
        and sync messages.

        passive:
        The port shall not place any messages on its communication path except
        for Pdelay_Req, Pdelay_Resp, Pdelay_Resp_Follow_Up, or signaling messages
        or management messages that are a required response to another management
        message.

        uncalibrated:
        This is a transient state to allow initialization of synchronization
        servos, updating of data sets when a new master port has been selected,
        and other implementation-specific activity.

        slave:
        The port is synchronizing to the selected master port."
        REFERENCE   "section 8.2.5.3.1 portDS.portState of [1]"
        ::= { ptpPortDataSetEntry 6 }

    ptpPortMinDelayReqInterval OBJECT-TYPE
        SYNTAX  Integer32 (-7..7)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This is the log to the base 2 of the delay request interval
        in seconds. This speifies the time to the members devices to
        send delay request messages when the port is in the master.
        It specify the minimum permitted mean time interval between
        successive Delay_Req messages, min delay request interval value is
        a compromise between the fluctuation in link delay and startup time
        and the communication and computation load imposed by transmission
        of these messages."
        REFERENCE   "section 8.2.5.3.2 portDS.logMinDelayReqInterval of [1]"
        DEFVAL { -4 }
        ::= { ptpPortDataSetEntry 7 }

    ptpPortLogAnnounceInterval OBJECT-TYPE
        SYNTAX  Integer32 (-3..6)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
          "This is the log to the base 2 of the mean Announce message interval
           in seconds."
        REFERENCE   "section 8.2.5.4.1 portDS.logAnnounceInterval of [1]"
        DEFVAL { -3 }
        ::= { ptpPortDataSetEntry 8 }

    ptpPortAnnounceReceiptTimeout OBJECT-TYPE
        SYNTAX  Integer32 (3..10)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
          "This is the Announce receipt time out value.
           This should be an integral multiple of announce interval
           in seconds"
        REFERENCE   "section 8.2.5.4.2 portDS.announceReceiptTimeout of [1]"
        DEFVAL { 3 }
        ::= { ptpPortDataSetEntry 9 }

    ptpPortSyncInterval OBJECT-TYPE
        SYNTAX  Integer32 (-7..0)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This is the logarithm to the base 2 of the sync message interval
         in seconds"
        REFERENCE   "section 8.2.5.4.3 portDS.logSyncInterval of [1]"
        DEFVAL { -4 }
        ::= { ptpPortDataSetEntry 10 }

    ptpPortDelayMechanism OBJECT-TYPE
        SYNTAX      ClockMechanismType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
          "This indicates the propagation delay measuring option used by the
           port in computing meanpathDelay."
        DEFVAL { e2e }
        ::= { ptpPortDataSetEntry 11 }

    ptpPortVersionNumber OBJECT-TYPE
        SYNTAX  Integer32 (2)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
           "This indicates the PTP version in use on the port."
        DEFVAL { 2 }
        ::= { ptpPortDataSetEntry 12 }

    ptpPortNotSlave  OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used in the alternate BMCA to prevent that a port
         can be placed in the SLAVE state."
        REFERENCE       "Section 6.3.1 and 6.3.2 of [2]"
        DEFVAL { true }
        ::= { ptpPortDataSetEntry 13 }

    ptpPortLocalPriority OBJECT-TYPE
        SYNTAX      Integer32 (1..255)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used in the alternate BMCA as a tie-breaker in the
         dataset comparison algorithm, in the event that all other previous
         attributes of the datasets being compared are equal."
        REFERENCE   "Section 6.3.1 and 6.3.2 of [2]"
        DEFVAL { 128 }
        ::= { ptpPortDataSetEntry 14 }

    ptpPortDestMacAddress OBJECT-TYPE
        SYNTAX      INTEGER {
                              forwardable    (1),
                              nonForwardable (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used in to select the destination MAC address
         inserted in the outgoing packets:
           forwardable:    01-1B-19-00-00-00
           nonForwardable: 01-80-C2-00-00-0E
        "
        REFERENCE   "Section 6.2.6 of [3]"
        DEFVAL { nonForwardable }
        ::= { ptpPortDataSetEntry 15 }

    ptpPortTxAsymmetryCompensation OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used to compensate in nanoseconds the asymmetric
         delay. It works in TX direction."
        DEFVAL { 0 }
        ::= { ptpPortDataSetEntry 16 }

    ptpPortRxAsymmetryCompensation OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "This attribute is used to compensate in nanoseconds the asymmetric
         delay. It works in RX direction."
        DEFVAL { 0 }
        ::= { ptpPortDataSetEntry 17 }

    ptpPortRowStatus OBJECT-TYPE
        SYNTAX  RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
        "RowStatus for creating the entries into this table.
         This object can't be modified."
        ::= { ptpPortDataSetEntry 18 }

    --
    --  Ptp Port alarms. Contains alarms of a particular PTP port
    --

    ptpPortAlarmTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpPortAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Table Contains PTP alarm information
                 for a particular port of boundary or an ordinary clock."
        ::= { ptpPortDataSet 2 }

    ptpPortAlarmEntry   OBJECT-TYPE
        SYNTAX      PtpPortAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains PTP alarm information for a particular port."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex,
                ptpPortIndex
              }
        ::= { ptpPortAlarmTable 1 }

    PtpPortAlarmEntry ::= SEQUENCE {
            ptpPortFaultyAlarm             AlarmStatus,
            ptpPortInitializingAlarm       AlarmStatus,
            ptpPortUncalibratedAlarm       AlarmStatus,
            ptpPortListeningAlarm          AlarmStatus,
            ptpPortActiveStatus            AlarmStatus
    }

    ptpPortFaultyAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpPortState is set to faulty(2)."
        ::=  { ptpPortAlarmEntry  1 }

    ptpPortInitializingAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpPortState is set to initializing(1).
            "
        ::=  { ptpPortAlarmEntry  2 }

    ptpPortUncalibratedAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpPortState is set to uncalibrated(8).
            "
        ::=  { ptpPortAlarmEntry  3 }

    ptpPortListeningAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpPortState is set to listening(4).
            "
        ::=  { ptpPortAlarmEntry  4 }

    ptpPortActiveStatus OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when ptpPortState is set to slave(9).
            "
        ::=  { ptpPortAlarmEntry  5 }

    --
    --  Ptp Radio Port alarms. Contains alarms of a Radio PTP port
    --

    ptpPortRadioAlarmTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpPortRadioAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Table Contains PTP alarm information
                 for a radio port of boundary or an ordinary clock."
        ::= { ptpPortDataSet 3 }

    ptpPortRadioAlarmEntry   OBJECT-TYPE
        SYNTAX      PtpPortRadioAlarmEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Contains PTP alarm information for a radio port."
        INDEX { ptpClockDomainIndex,
                ptpClockTypeIndex,
                ptpClockInstanceIndex,
                ptpPortIndex
              }
        ::= { ptpPortRadioAlarmTable 1 }

    PtpPortRadioAlarmEntry ::= SEQUENCE {
            ptpPortRadioCapacityAlarm   AlarmStatus
    }

    ptpPortRadioCapacityAlarm OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This alarm is raised when the capacity of a radio link
             is not big enough to transport PTP packets."
        ::=  { ptpPortRadioAlarmEntry  1 }

    --
    --  Ptp Port alarm severities.
    --

    ptpPortFaultyAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to
             ptpPortFaultyAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { majorTrapEnable }
        ::= { ptpPortDataSet 4 }

    ptpPortInitializingAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to
             ptpPortInitializingAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { warningTrapEnable }
        ::= { ptpPortDataSet 5 }

    ptpPortUncalibratedAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to
             ptpPortUncalibratedAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { warningTrapEnable }
        ::= { ptpPortDataSet 6 }

    ptpPortListeningAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object defines the severity associated to
             ptpPortListeningAlarm and enables or disables the
             sending of the SNMP Trap on the alarm status transition.
            "
        DEFVAL      { warningTrapEnable }
        ::= { ptpPortDataSet 7 }

    ptpPortActiveStatusSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object enables or disables the sending of the SNMP Trap
             on ptpPortActiveStatus transition.
            "
        DEFVAL      { statusTrapEnable }
        ::= { ptpPortDataSet 8 }

    ptpPortRadioCapacityAlarmSeverityCode OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object enables or disables the sending of the SNMP Trap
             on ptpPortRadioCapacityAlarm transition.
            "
        DEFVAL      { majorTrapEnable }
        ::= { ptpPortDataSet 9 }

--
-------  End of Ptp Port data set.


-------  Begin of PTP Radio Asymmetry data set.
--       Configuration asymmetry of a specific Radio unit.
--

    ptpRadioAsymmetryDataSetTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF PtpRadioAsymmetryDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Table contains delay offset for asymmetries compensation for the Radio unit."
        ::= { ptpRadioAsymmetryDataSet 1 }

    ptpRadioAsymmetryDataSetEntry   OBJECT-TYPE
        SYNTAX      PtpRadioAsymmetryDataSetEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
                "Each ntry contains delay offset for asymmetries compensation for a specific Radio unit."
        INDEX { ptpRadioBrIndex
              }
        ::= { ptpRadioAsymmetryDataSetTable 1 }

    PtpRadioAsymmetryDataSetEntry ::= SEQUENCE {
            ptpRadioBrIndex    Integer32,
            ptpRadioOffset     Integer32
    }

	
    ptpRadioBrIndex  OBJECT-TYPE
        SYNTAX       Integer32
        MAX-ACCESS   read-only
        STATUS       current
        DESCRIPTION
        "This is the index in radioTable of this unit.
         This object can't be modified."
        ::= { ptpRadioAsymmetryDataSetEntry 1 }


    ptpRadioOffset  OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
        "This object is an offset in nanoseconds for asymmetry compensation and 
		can have both positive and negative values."
        DEFVAL { 0 }
        ::= { ptpRadioAsymmetryDataSetEntry 2 }

--
-------  End of PTP Radio Asymmetry data set.

END