-- Copyright (C) 2014 by  HUAWEI TECHNOLOGIES. All rights reserved.
-- 
-- Description: HUAWEI Transmission Alarm Damping MIB
-- Reference:
-- Version: V2.01
-- History:
-- <author>,  <date>,  <contents>
-- Jiangwei   2006-6-28
-- ==================================================================

-- ==================================================================
-- 
-- Variables and types be imported
--
-- ==================================================================

HUAWEI-TAD-MIB DEFINITIONS ::= BEGIN
IMPORTS
    
    MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, OBJECT-IDENTITY
        FROM SNMPv2-SMI  
        
    TEXTUAL-CONVENTION, DisplayString, DateAndTime
      FROM SNMPv2-TC
      
    OBJECT-GROUP, MODULE-COMPLIANCE            
      FROM SNMPv2-CONF    
      
    hwDatacomm
        FROM HUAWEI-MIB

    ifIndex,InterfaceIndex
        FROM IF-MIB ;
        
    hwTAD MODULE-IDENTITY
       LAST-UPDATED "201403191100Z"        
         ORGANIZATION
            "Huawei Technologies Co.,Ltd."
        CONTACT-INFO 
            "Huawei Industrial Base
              Bantian, Longgang
               Shenzhen 518129
               People's Republic of China
               Website: http://www.huawei.com
               Email: support@huawei.com
              "
          DESCRIPTION
            "The Custom damping MIB module is defined to manage the configuration under system or interface view."

      REVISION "201403191100Z"        
            DESCRIPTION  
              "Update hwTADAlarmType , add object-type prefectca(40)."
      REVISION "200606281600Z"        
            DESCRIPTION  
              "The Custom damping MIB module is defined to manage the configuration under system or interface view."
            ::= { hwDatacomm 128 }
              

HWEnableValue ::= TEXTUAL-CONVENTION
    STATUS      current
    DESCRIPTION
        "A simple status value for the object."
    SYNTAX      INTEGER { enable(1), disable(2) }
    
-- ==================================================================
--
-- ======================= Definitions begin =========================
--
-- ==================================================================
    
hwTADObjects OBJECT IDENTIFIER ::= { hwTAD 1 }
    

-- ======================= interface table =========================

    hwTADInterfaceTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF HwTADInterfaceEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "Transmission alarm damping interface configuration table."
        ::= { hwTADObjects  1 }


    hwTADInterfaceEntry  OBJECT-TYPE
        SYNTAX HwTADInterfaceEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "The entry of a SDH or SONET interface with damping function enabled."
        INDEX   { hwTADInterfaceIndex }
        ::= { hwTADInterfaceTable 1}


    HwTADInterfaceEntry  ::=
    SEQUENCE {
        hwTADInterfaceIndex    InterfaceIndex  ,
        hwTADFilterEnable    HWEnableValue   ,
        hwTADFilterExpireTime   Integer32   ,
        hwTADDampingEnable  HWEnableValue    ,
        hwTADSuppress   Integer32   ,
        hwTADCeiling    Integer32    ,
        hwTADReuse  Integer32   ,
        hwTADDecayOk  Integer32   ,
        hwTADDecayNg  Integer32   ,
        hwTADResetStatistics   INTEGER   ,
        hwTADResetTime   DateAndTime   ,
        hwTADB3tcaThreshold  Integer32   ,
        hwTADSdbereThreshold  Integer32   ,
        hwTADSfbereThreshold  Integer32   ,
        hwTADB1tcaThreshold  Integer32   ,
        hwTADB2tcaThreshold  Integer32   ,
        hwTADBip2tcaThreshold  Integer32
        }


    hwTADInterfaceIndex  OBJECT-TYPE
        SYNTAX    InterfaceIndex 
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "Index number of the interface."
        ::= { hwTADInterfaceEntry 1 }


    hwTADFilterEnable  OBJECT-TYPE
        SYNTAX  HWEnableValue 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "Whether filter function is enabled."
        DEFVAL      { disable }
        ::= { hwTADInterfaceEntry 2 }
        

    hwTADFilterExpireTime  OBJECT-TYPE
        SYNTAX  Integer32(20..10000)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "How long the alarm will be postponed to process. Unit: millisecond."
        DEFVAL      { 50 }
        ::= { hwTADInterfaceEntry 3 }
        
        
    hwTADDampingEnable  OBJECT-TYPE
        SYNTAX  HWEnableValue
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "Whether damping function is enabled."
        DEFVAL      { disable }
        ::= { hwTADInterfaceEntry 4 }

    
    hwTADSuppress  OBJECT-TYPE
        SYNTAX  Integer32(2..19999)
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "The suppressing value. When figure-of-merit of alarm exceeds this value,
        this alarm will be damped."
        DEFVAL      { 2000 }
        ::= { hwTADInterfaceEntry 5 }
        
             
    hwTADCeiling OBJECT-TYPE
        SYNTAX  Integer32(1001..20000) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "The ceiling value. Figure-of-merit can't exceed this value. The ceiling
        value must be larger than suppressing value."
        DEFVAL      { 6000 }
        ::= { hwTADInterfaceEntry 6 }
        
        
    hwTADReuse OBJECT-TYPE
        SYNTAX  Integer32(1..19998) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "The reusing value. When figure-of-merit becomes lower than this value.
        The alarm will be reused (exit from suppressing status). The reusing value must be
        less than suppressing value."
        DEFVAL      { 750 }
        ::= { hwTADInterfaceEntry 7 }
        
    
    hwTADDecayOk OBJECT-TYPE
        SYNTAX  Integer32(500..10000) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "The half decay time when alarm status is down. Unit: millisecond."
        DEFVAL      { 1000 }
        ::= { hwTADInterfaceEntry 8 }       

   
    hwTADDecayNg OBJECT-TYPE
        SYNTAX  Integer32(500..10000) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "The half decay time when alarm status is up. Unit: millisecond."
        DEFVAL      { 1000 }
        ::= { hwTADInterfaceEntry 9 }          


    hwTADResetStatistics OBJECT-TYPE
        SYNTAX  INTEGER{
        reset(1),
        unreset(2)
        }
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "Whether to reset alarm statistics. 1 means resetting statistics once."
        DEFVAL      { 2 }
        ::= { hwTADInterfaceEntry 10 }
        
    hwTADResetTime OBJECT-TYPE
        SYNTAX  DateAndTime
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "Last reset time."
        ::= { hwTADInterfaceEntry 11 }


    hwTADB3tcaThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "B3tca threshold in form of 10e-n."
        DEFVAL      { 6 }
        ::= { hwTADInterfaceEntry 12 }


    hwTADSdbereThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "Sdbere threshold in form of 10e-n."
        DEFVAL      { 6 }
        ::= { hwTADInterfaceEntry 13 }


    hwTADSfbereThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "Sfbere threshold in form of 10e-n."
        DEFVAL      { 3 }
        ::= { hwTADInterfaceEntry 14 }


    hwTADB1tcaThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "B1tca threshold in form of 10e-n."
        DEFVAL      { 6 }
        ::= { hwTADInterfaceEntry 15 }    


    hwTADB2tcaThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "B2tca threshold in form of 10e-n."
        DEFVAL      { 6 }
        ::= { hwTADInterfaceEntry 16 }


    hwTADBip2tcaThreshold OBJECT-TYPE
        SYNTAX  Integer32(3..9) 
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION   "Bip2tca threshold in form of 10e-n."
        DEFVAL      { 6 }
        ::= { hwTADInterfaceEntry 17 }     

  
-- ======================= alarm table =========================

    hwTADAlarmTable  OBJECT-TYPE
        SYNTAX SEQUENCE OF HwTADAlarmEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "Transmission alarm damping alarm configuration table."
        ::= { hwTADObjects  2 }


    hwTADAlarmEntry  OBJECT-TYPE
        SYNTAX HwTADAlarmEntry
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "The entry of an alarm."
        INDEX   { hwTADAlarmIfIndex, hwTADAlarmType }
        ::= { hwTADAlarmTable 1}


    HwTADAlarmEntry  ::=
    SEQUENCE {
        hwTADAlarmIfIndex    InterfaceIndex  ,
        hwTADAlarmType    INTEGER   ,
        hwTADAlarmIfDown   HWEnableValue   ,
        hwTADAlarmLog  HWEnableValue    ,
        hwTADAlarmStatus   INTEGER   ,
        hwTADAlarmInFilter    INTEGER    ,
        hwTADAlarmFigure  DisplayString   ,
        hwTADAlarmInSuppress  INTEGER   ,
        hwTADAlarmFlappingCount  Counter32   ,
        hwTADAlarmSuppressCount  Counter32
        }


    hwTADAlarmIfIndex  OBJECT-TYPE
        SYNTAX    InterfaceIndex 
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "Index number of the interface."
        ::= { hwTADAlarmEntry 1 }


    hwTADAlarmType  OBJECT-TYPE
        SYNTAX  INTEGER{
        auais(1),
        b3tca(2),
        lais(3),
        lof(4),
        lom(5),
        lop(6),
        los(7),
        lrdi(8),
        lrei(9),
        oof(10),
        pais(11),
        prdi(12),
        prei(13),
        pplm(14),
        rdool(15),
        rrool(16),
        sdbere(17),
        sfbere(18),
        trool(19),
        puneq(20),
        lcd(21),
        wlnk(22),
        oduais(23),
        odulck(24),
        oduoci(25),
        otuais(26),
        otuom(27),
        otusdber(28),
        otusfber(29),
        pmbdi(30),
        pmtim(31),
        rlof(32),
        rlos(33),
        roof(34),
        smbdi(35),
        smiae(36),
        smtim(37),
        b1tca(38),
        b2tca(39),
        prefectca(40)
        }
        MAX-ACCESS not-accessible
        STATUS current
        DESCRIPTION "Index number of the alarm. The range is from 1 to 39, corresponding to:
        auais, b3tca, lais, lof, lom, lop, los, lrdi, lrei, oof, pais, prdi, prei, pplm, rdool,
        rrool, sdbere, sfbere, trool, puneq, lcd, wlnk, oduais, odulck, oduoci, otuais, otulom,
        otusdber, otusfber, pmbdi, pmtim, rlof, rlos, roof, smbdi, smiae, smtim, b1tca, b2tca, prefectca."
        ::= { hwTADAlarmEntry 2 }
        

    hwTADAlarmIfDown  OBJECT-TYPE
        SYNTAX  HWEnableValue
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "Whether this alarm leads to interface down. In default lais, lof and los
        are enabled to lead interface down."
        ::= { hwTADAlarmEntry 3 }
        
        
    hwTADAlarmLog  OBJECT-TYPE
        SYNTAX  HWEnableValue
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION "Whether this alarm will be logged. In default all alarm types won't be logged."
        DEFVAL      { disable }
        ::= { hwTADAlarmEntry 4 }

    
    hwTADAlarmStatus  OBJECT-TYPE
        SYNTAX  INTEGER{
        up(1),
        down(2)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION "The status of the alarm. 1 means alarm is up, 2 means alarm is down."
        ::= { hwTADAlarmEntry 5 }
        
             
    hwTADAlarmInFilter OBJECT-TYPE
        SYNTAX  INTEGER {
        in(1),
        out(2)
        } 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "Whether this alarm is in filtering status. 1 means alarm is in filtering status,
        2 means alarm isn't in filtering status."
        ::= { hwTADAlarmEntry 6 }
        
        
    hwTADAlarmFigure OBJECT-TYPE
        SYNTAX  DisplayString 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "This figure is used to evaluate the stability of the alarm. Large
        value means un-stability."
        ::= { hwTADAlarmEntry 7 }
        
    
    hwTADAlarmInSuppress OBJECT-TYPE
        SYNTAX  INTEGER{
        suppressed(1),
        unsuppressed(2)
        } 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "Whether this alarm is in suppressing status. 1 means alarm is
        in suppressing status, 2 means alarm isn't in suppressing status."
        ::= { hwTADAlarmEntry 8 }       

   
    hwTADAlarmFlappingCount OBJECT-TYPE
        SYNTAX  Counter32 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "How many times alarm's status changed."
        ::= { hwTADAlarmEntry 9 }          


    hwTADAlarmSuppressCount OBJECT-TYPE
        SYNTAX  Counter32 
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION   "How many times alarm is suppressed."
        ::= { hwTADAlarmEntry 10 }  

        
-- ==================================================================
-- HUAWEI-CUSTOM-DAMPING-MIB MIB - Conformance Information
-- ==================================================================        
        
    hwTADConformance OBJECT IDENTIFIER ::= { hwTAD 2 }

    hwTADGroups OBJECT IDENTIFIER ::= { hwTADConformance 1 }


-- ==================================================================
-- Units of conformance
-- ==================================================================

hwTADInterfaceGroup OBJECT-GROUP
    OBJECTS {
        hwTADFilterEnable   ,
        hwTADFilterExpireTime   ,
        hwTADDampingEnable  ,
        hwTADSuppress   ,
        hwTADCeiling  ,
        hwTADReuse   ,
        hwTADDecayOk   ,
        hwTADDecayNg   ,
        hwTADResetStatistics   ,
        hwTADResetTime   ,
        hwTADB3tcaThreshold   ,
        hwTADSdbereThreshold   ,
        hwTADSfbereThreshold
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing device level control
        and status information for the interface."
    ::= { hwTADGroups 1 }      
           
hwTADAlarmGroup OBJECT-GROUP
    OBJECTS {
        hwTADAlarmIfDown   ,
        hwTADAlarmLog   ,
        hwTADAlarmStatus   ,
        hwTADAlarmInFilter   ,
        hwTADAlarmFigure   ,
        hwTADAlarmInSuppress  ,
        hwTADAlarmFlappingCount  ,
        hwTADAlarmSuppressCount  
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing device level control
        and status information for the alarm."
    ::= { hwTADGroups 2 } 
  
hwTADCompliances OBJECT IDENTIFIER ::= { hwTADConformance 2 }  
    hwTADCompliance MODULE-COMPLIANCE
         STATUS current
         DESCRIPTION
            "The core compliance statement for all TAD implementations."
         MODULE
         MANDATORY-GROUPS  {
             hwTADInterfaceGroup,
             hwTADAlarmGroup
         }
         ::= { hwTADCompliances 1 }
         
END